236 Using the FC-FC routing service
switch:admin>
portcfgexport 7/10 -a 1 -f 30
switch:admin>
portcfgexport 7/10
Port 7/10 info
Admin: enabled
State: NOT OK
Pid format: Not Applicable
Operate mode: Brocade Native
Edge Fabric ID: 30
Preferred Domain ID: 160
Front WWN: 50:06:06:9e:20:38:6e:1e
Fabric Parameters: Auto Negotiate
R_A_TOV: Not Applicable
E_D_TOV: Not Applicable
Authentication Type: None
DH Group: N/A
Hash Algorithm: N/A
Edge fabric's primary wwn: N/A
Edge fabric's version stamp: N/A
portCfgExport options
This port can now connect to another switch. The following list describes the options for the
portCfgExport
command. For more information about the
portCfgExport
and
portCfgVexport
commands, see the
Fabric OS Command Reference Manual
.
-a
Sets the EX_Port to enabled (1) or disabled (2). Admin use only.
-f
Sets the fabric ID (1 to 128). Each edge fabric must have a unique ID, and
EX_Ports (or VEX_Ports) connected to the same edge fabric must have the same
fabric ID. The default value is the port number divided by 3, plus 2 and rounded
down.
-r
Sets the R_A_TOV used for port negotiation (2000 - 120000).
-e
Sets the E_D_TOV used for port negotiation (1000 - 60000).
-d
Preferred front domain ID (1-239). This command enforces the use of the same
preferred front domain ID for all the ports connected to the same edge fabric.
When this option is specified, the preferred front domain ID is compared against
the online ports. If the preferred front domain ID is different, an error message is
issued and the command fails.
When the -d option is not specified, if there are online ports connected to the
same edge fabric, the preferred front domain ID is set to the preferred front
domain ID of those online ports. Otherwise, if there are offline ports that are set
to EX_Port, the preferred front domain ID is set to those offline ports. If none of the
above conditions apply, the existing value is left untouched.
-p
Sets the PID format (0-native, 1-core, 2-extended-edge). The value must match the
edge fabric setting. The default value is 1.
-t
Sets the negotiate fabric parameters (1-enable, 2-disable)
-m
Sets the port mode. (0-Brocade, 1-Open, 2-McDATA Fabric, 3-McDATA Fabric
Legacy). This command enforces the use of the same port mode for all the ports
connected to the same edge fabric.
When this option is specified, the port mode is compared against the online
ports. If the modes are different, an error message is issued and the command
fails.
When the -m option is not specified:
If there are online ports connected to the same edge fabric, the mode is set to the
mode of those online ports. Otherwise, if there are offline ports that are set to
EX_Port, the mode is set to those offline ports.
If none of the above conditions apply, the existing value is left untouched.
Summary of Contents for AA979A - StorageWorks SAN Switch 2/8V
Page 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Page 16: ...16 ...
Page 20: ...18 ...
Page 24: ...24 Introducing Fabric OS CLI procedures ...
Page 116: ...118 Maintaining configurations ...
Page 170: ...172 Managing administrative domains ...
Page 200: ...202 Installing and maintaining firmware ...
Page 222: ...224 Routing traffic ...
Page 274: ...286 Administering FICON fabrics ...
Page 294: ...306 Working with diagnostic features ...
Page 350: ...362 Administering Extended Fabrics ...
Page 438: ...440 Configuring the PID format ...
Page 444: ...446 Configuring McData Open Fabric mode ...
Page 450: ...452 Understanding legacy password behaviour ...