MEMory:T
ABLe:FREQuency
MEMory:TABLe:FREQuency
8
<
:
fr
e
q,fr
e
q,fr
e
q,...fr
e
q
MAXimum
MINimum
9
=
;
The
\MEMory:T
ABLe:FREQuency"
command
is
used
to
load
the
frequency
p oints
in
to
the
lev
el
correct
table
selected
using
the
\MEMory:T
ABLe:SELect"
command.
The
parameter
is
as
follows:
fr
e
q
The
frequency
p oints
that
make
up
the
frequency
p ortion
of
a
lev
el
correct
table.
Eac
h
\freq"
parameter
can
b e
a
n
umeric
v
alue
or
one
of
2
optional
parameters.
These
are
explained
further
b elow:
If
the
\freq"
parameter
is
a
n
umeric
v
alue,
the
parameter
range
is
1
GHz
to
20
GHz
for
the
HP
70340A
and
0.01
GHz
to
20
GHz
for
the
HP
70340A.
If
the
\freq"
parameter
is
replaced
with
MAXimum ,
that
frequency
elemen
t
of
the
lev
el
correct
table
will
b e
set
to
its
maximum
allo
w
able
v
alue.
If
the
\freq"
parameter
is
replaced
with
MINimum ,
that
frequency
elemen
t
of
the
lev
el
correct
table
will
b e
set
to
its
minimum
allo
w
able
v
alue.
The
string
of
frequency
p oints
m
ust
b e
separated
b
y
commas
and
can
b e
from
2
to
401
frequency
p oints
long.
If
the
string
of
frequency
p oints
is
not
in
ascending
order,
an
error
message
is
generated
and
the
string
of
frequency
p oints
is
rejected
(the
previous
frequency
p oints
in
the
table
are
unaected).
If
a
frequency
p oint
en
try
is
made
that
is
not
within
its
allo
w
able
range,
an
error
message
will
b e
generated
and
the
parameter
will
b e
set
to
either
its
upp er
or
low
er
limit.
The
resolution
for
all
frequency
p oints
is
1
kHz.
All
tables
are
preset
at
the
factory
with
no
frequency
p oints
loaded.
Once
loaded
with
frequency
p oints,
pressing
the
4
INSTR
PRESET
5
( 4
I-P
5)
k
ey
has
no
eect
on
frequency
p oints
loaded
in
to
the
tables.
Note
The
total
n
um
b er
of
frequency
p oints
loaded
using
this
command
m
ust
b e
iden
tical
to
the
n
um
b er
of
correction
factors
loaded
with
the
\MEMory:T
ABLe:LOSS[:MA
GNitude]"
command.
If
they
aren't
iden
tical,
an
error
message
will
b e
generated
when
y
ou
try
to
use
the
table
to
correct
p o
w
er
at
the
RF
OUTPUT
connector.
Query
Syntax
MEMory:TABLe:FREQuency?
MAXimum
MINimum
Returned
format:
fdata
< NL>
Where:
fdata
::=
The
string
of
frequency
p oints
(separated
b
y
commas)
that
are
curren
tly
loaded
in
the
table
selected
with
the
\MEMory:T
ABLe:SELect"
command
if
no
argumen
t
is
used.
7-38
Programming
Commands
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for 70340A
Page 94: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 110: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 224: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 402: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 424: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 436: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...