[SOURce[1]:]PO
W
er[:LEV
el]
2
SOURce
2
1
3
:
3
POWer
2
:LEVel
32
:IMMediate
32
:AMPLitude
3
8
>
>
>
>
>
>
<
>
>
>
>
>
>
:
ampl
MAXimum
MINimum
UP
DOWN
DEFault
9
>
>
>
>
>
>
=
>
>
>
>
>
>
;
The
\[SOURce[1]:]POW
er[:LEV
el]"
command
sets
the
output
p o
w
er
lev
el
of
the
Signal
Generator.
The
parameters
are
as
follo ws:
ampl
Sets
the
Signal
Generator
output
p o
w
er
lev
el.
The
allo
w
able
range
for
the
parameter
is
0100
dBm
to
+30
dBm
if
option
1E1
is
installed
and
015
dBm
to
+30
dBm
if
option
1E1
is
not
installed.
MAXimum
Sets
the
Signal
Generator
output
p o
w
er
lev
el
to
the
maximum
allo w
able
v
alue.
MINim
um
Sets
the
Signal
Generator
output
p o
w
er
lev
el
to
the
minimum
allo w
able
v
alue.
UP
Increases
the
Signal
Generator
output
p o
w
er
lev
el
b
y
the
curren
t
p o
w
er
lev
el
incremen
t
v
alue.
DO
WN
Decreases
the
Signal
Generator
output
p o
w
er
lev
el
b
y
the
curren
t
p o
w
er
lev
el
incremen
t
v
alue.
DEF
ault
Sets
the
Signal
Generator
output
p o
w
er
lev
el
to
its
default
(preset)
v
alue.
The
allo w
able
range
for
the
ampl
parameter
is
0100
dBm
to
+30
dBm
if
option
1E1
is
installed
and
015
dBm
to
+30
dBm
if
option
1E1
is
not
installed.
Note
The
actual
maximum
in
ternally
lev
eled
output
p o
w
er
for
y
our
instrumen
t
at
a
given
frequency
can
b e
found
b
y
increasing
the
Signal
Generator
output
p o
w
er
un
til
the
UNLEVELED
LED
lights.
If
a
p o
w
er
lev
el
en
try
is
made
that
is
not
within
the
allo
w
able
parameter
range,
an
error
message
will
b e
generated
and
the
parameter
will
b e
set
to
either
its
maximum
or
minimum
limit.
P
o
w
er
lev
el
resolution
is
0.01
dB.
The
preset
v
alue
is
090
dBm
if
option
1E1
is
installed
and
0
dBm
if
option
1E1
is
not
installed.
When
the
p o
w
er
lev
el
is
mo
died,
the
Signal
Generator
circuitry
will
ensure
that
transitions
from
one
p o
w
er
lev
el
to
another
will
not
allo
w
the
lev
el
to
exceed
the
maximum
of
the
t
w
o
lev
els
if
the
instrumen
t
is
in
CW
mo
de
(not
mo
dulated).
If
the
RF
output
is
b eing
amplitude
mo
dulated
or
pulse
mo
dulated,
the
Signal
Generator
circuitry
will
ensure
that
transitions
from
one
p o
w
er
lev
el
to
another
will
not
exceed
the
maximum
of
the
t
w
o
p o
w
er
lev
els
b
y
more
than
0.5
dB
t
ypical.
Note
Changing
frequency
or
p o
w
er
lev
el
while
pulse
mo
dulating
the
output
triggers
an
in
ternal
p o
w
er
lev
el
calibration.
This
calibration
includes
a
CW
burst
Programming
Commands
7-95
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for 70340A
Page 94: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 110: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 224: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 402: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 424: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 436: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...