command/query
The
command allows you to construct a pattern recognizer
term for the timing analyzer trigger on a per label basis. Each command
deals with only one label in the given pattern; therefore, a complete timing
trace
could require several commands. Since a label can
contain up to 32 bits, the range of the pattern value will be between 0 and
The value may be expressed in binary (#B), octal
hexadecimal
or decimal (default). When the value of a pattern is
expressed in binary, it represents the bit
for the label inside the
pattern recognizer term. Since a pattern value can contain don’t cares,
the pattern specification parameter is handled as a string of characters
instead of a number.
The
query returns the pattern specification for the specified
label in the base previously defined for the label.
Command Syntax:
1
c label-name
pattern-spec
where:
c label-name
:: = string of up to 6 alphanumeric characters
pattern-spec
::
1
. .
. .
. .
.
Example:
OUTPUT XXX;
‘ D A T A ’ , ‘ 2 5 5 ” ’
HP
Programming Reference
Subsystem
16-9