Granulate quantities
¾
Operate first with the basic setting.
¾
If granulate is blown out, close the gate valve
in small increments until no more granulate is
blown out from the furrow.
¾
For higher amount of granulate, open the gate
valve accordingly.
NOTE
For use with micro-granular compound, the fan
must be set to min. 4500 rpm.
NOTE
The pneumatic system of the micro-granulate
facility is not monitored!
Hoses and distributor of the micro-granulate
facility must therefore be checked and cleaned
before use and several times during use for leak
tightness and deposits.
Granulate
placement
In the standard design granulate is placed be-
tween the coulter discs in the seed furrow:
With optional equipment granulate can also be
placed on the surface behind the press rollers.
¾
Reconnect the hose for this purpose:
1
2
1 Connection for placement in seed furrow
2 Connection for placement on surface
For wider distribution granulate can be directed
onto a deflector plate.
¾
Loosen the nut and fold the
baffle plate down.
¾
After each conversion tighten the nut with the
spanner.