Orbit 7120plus/7190g User Guide
9
Each bar code above also programs the following suffixes for each symbology:
* Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B HHBCR-1, and IBM 4683
Port 17 Interfaces
**Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface
RS485 Packet Mode
The following selection allows you to break up large bar code data into smaller
packets on an IBM POS terminal. To break up large bar codes into small packets,
scan the
Packet Mode On
bar code below. Scan the
Packet Mode Off
bar code if
you want large bar code data to be sent to the host in a single chunk.
Default =
Packet Mode Off.
RS485 Packet Length
If you are using Packet mode, you can specify the size of the data “packet” that is
sent to the host. Scan the
Packet Length
bar code, then the packet size (from 20 -
256) from the
beginning on page 225 of this manual, then
Save
.
Default = 40
.
Symbology
Suffix
Symbology
Suffix
EAN 8
0C
Code 39
00 0A 0B
EAN 13
16
Interleaved 2 of 5
00 0D 0B
UPC A
0D
Code 128 *
00 0A 0B
UPC E
0A
Code 128 **
00 18 0B
MaxiCode
00 2F 0B
IBM Port 17 Interface
IBM Port 9B
HHBCR-2 Interface
* Packet Mode Off
Packet Mode On
Packet Length
Summary of Contents for ORBIT 7120PLUS
Page 1: ...User Guide Orbit 7120plus 7190g Hybrid Presentation Scanner ...
Page 12: ...x Orbit 7120plus 7190g User Guide ...
Page 14: ...xii Orbit 7120plus 7190g User Guide ...
Page 98: ...84 Orbit 7120plus 7190g User Guide ...
Page 161: ...Orbit 7120plus 7190g User Guide 147 Don t Transmit Check Digit ...
Page 162: ...148 Orbit 7120plus 7190g User Guide ...
Page 188: ...174 Orbit 7120plus 7190g User Guide ...
Page 224: ...210 Orbit 7120plus 7190g User Guide ...
Page 236: ...222 Orbit 7120plus 7190g User Guide ...
Page 239: ...Orbit 7120plus 7190g User Guide 225 Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Page 241: ...Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 7190 EN UG Rev A 2 17 ...