178
Orbit 7120plus/7190g User Guide
Response:
CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on.
Example:
What are the device’s settings for all Codabar selections?
Enter:
cbr?.
Response:
CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands. First,
you must send a serial menu command for triggering (
is in serial trigger mode, the trigger is activated and deactivated by sending the fol-
lowing commands:
Activate:
SYN T CR
Deactivate:
SYN U CR
The scanner scans until a bar code has been read, until the deactivate command is
sent, or until the serial time-out has been reached (see
for a description, and the serial command on
Summary of Contents for ORBIT 7120PLUS
Page 1: ...User Guide Orbit 7120plus 7190g Hybrid Presentation Scanner ...
Page 12: ...x Orbit 7120plus 7190g User Guide ...
Page 14: ...xii Orbit 7120plus 7190g User Guide ...
Page 98: ...84 Orbit 7120plus 7190g User Guide ...
Page 161: ...Orbit 7120plus 7190g User Guide 147 Don t Transmit Check Digit ...
Page 162: ...148 Orbit 7120plus 7190g User Guide ...
Page 188: ...174 Orbit 7120plus 7190g User Guide ...
Page 224: ...210 Orbit 7120plus 7190g User Guide ...
Page 236: ...222 Orbit 7120plus 7190g User Guide ...
Page 239: ...Orbit 7120plus 7190g User Guide 225 Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Page 241: ...Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 7190 EN UG Rev A 2 17 ...