FUEL SYSTEM (PGM-FI)
6-59
6. Turn the ignition switch "ON" then disconnect
the jumper wire from the ECT sensor 3P (Gray)
connector while the MIL is blinking (reset receiv-
ing pattern) for 10 seconds.
7. Check if the MIL blinks.
8. Turn the ignition switch "OFF".
9. Connect the ECT sensor (Gray) 3P connector.
JUMPER WIRE
3P (GRAY)
CONNECTOR
within 10 sec.
0.1 sec.
MIL ON
MIL OFF
RESET RECEIVING PATTERN
SUCCESSFUL PATTERN
TP SENSOR IS
RESET
SUCCESSFULLY.
If the jumper wire is connected for more than 10 seconds, the MIL will stay ON (unsuccessful
pattern). Try again from the step 4.
After disconnection of the jumper wire, the MIL should start blinking (successful pattern).
ON
OFF
IGNITION
SWITCH
and
1.2 sec.
0.3 sec.
0.3 sec.
3P (GRAY) CONNECTOR