'61HN252' by American Honda Motor Co. - Page 437 of 540
http://services.honda.com/ServiceManual/SVC_MNL/61HN253/61HN2...
1 of 1
3/9/2008 11:22 PM
[2005-2008] [TRX500 FA/FGA]
ELECTRIC STARTER
STARTER RELAY VOLTAGE
Measure the voltage between the Yellow/red wire
terminal (+) of the harness side 2P connector and
YELLOW/RED(+)
ground ().
If the battery voltage appears only when the starter
switch is pushed with the ignition switch ON, the
circuit is normal.
OPERATION CHECK
CONNECTOR
GROUND(-)
Disconnect battery positive (+) cable and starter
motor cable from the starter relay switch.
Connect the fully charged 12 V battery positive ter-
minal to the Yellow/red wire terminal and negative
terminal to the
Light green/red
wire terminal of the
relay switch side 2P connector.
STARTER RELAY
There should be continuity between the cable termi-
SWITCH
nals while the battery is connected, and no continu-
ity when the battery is disconnected.
BATTERY
DIODE
INSPECTION
Remove the following:
seat (page 2-4)
fuel tank heat guard (page 8-6)
Remove the gear position (neutral) switch diode
and brake switch diode from the wire harness.
BRAKE SWITCH
GEAR POSITION
DIODE
SWITCH DIODE
Check for continuity between the diode terminals.
When there is continuity, a small resistance value
will register.
If there is continuity in one direction, the diode is
normal.
BRAKE SWITCH
GEAR POSITION
DIODE
SWITCH DIODE
21-13