BATTERY/CHARGING SYSTEM
ALTERNATOR CHARGING COIL
INSPECTION
Remove the recoil starter cover
(page 2-4).
5P (NATURAL) CONNECTOR
Disconnect the alternator 5P (Natural) connector.
Check the connector for loose contacts or corroded
terminals.
Measure the resistance between the Yellow wire
5P (NATURAL) CONNECTOR
terminals of the alternator side connector.
STANDARD: 0.1 1.0
Ω
(at 20
°
C/68
°
F)
Check for continuity between each Yellow wire ter-
minal of the alternator side connector and ground.
There should be no continuity.
Replace the alternator stator if resistance is out of
specification, or if any wire has continuity to
ground.
Refer to
page 11-8
for alternator stator replacement.
REGULATOR/RECTIFIER
WIRE HARNESS INSPECTION
Disconnect the regulator/rectifier 3P (Black) connec-
3P (GRAY)
3P (BLACK)
tor and 3P (Gray) connector.
CONNECTOR
CONNECTOR
Check the connectors for loose contacts or corroded
terminals.
REGULATOR/RECTIFIER
19-9