53
“A” Function
A
B
Defaults
Func.
Code
Name
Description
Initial data
Units
Torque boost select
Two options:
Manual torque boost
Automatic torque boost
00
Torque boost select,
2
nd
motor
00
Manual torque boost
value
Can boost starting torque
between 0 and 20% above
normal V/f curve,
range is 0.0 to 20.0 %
1.0
%
Manual torque boost
value, 2
nd
motor
1.0
%
Manual torque boost
frequency
Sets the frequency of the V/f
breakpoint A in graph (top of
previous page) for torque
boost,
range is 0.0 to 50.0 %
5.0
%
Manual torque boost
frequency,
2
nd
motor
5.0
%
V/f characteristic curve
Four available V/f curves;
Constant torque
Reduced torque (1.7)
Free V/F
00
V/f characteristic curve,
2
nd
motor
00
V/f gain
Sets voltage gain of the
inverter, range is 20. to 100.%
100.
%
V/f gain, 2
nd
motor
100.
%
Voltage compensation
gain for automatic
torque boost
Sets voltage compensation
gain under automatic torque
boost, range is 0. to 255.
100.
Voltage compensation
gain for automatic
torque boost,
2
nd
motor
100.
Slip compensation gain
for automatic torque
boost
Sets slip compensation gain
under automatic torque boost,
range is 0. to 255.
100.
Slip compensation gain
for automatic torque
boost,
2
nd
motor
100.
DC braking enable
Three options; select codes:
Disable
Enable during stop
Frequency detection
00
DC braking frequency
The frequency at which DC
braking begins,
Range is from the start
frequency (
) to 60Hz
0.5
Hz
DC braking wait time
The delay from the end of
controlled deceleration to start
of DC braking (motor free
runs until DC braking begins),
range is 0.0 to 5.0 sec.
0.0
s
DC braking force for
deceleration
Level of DC braking force,
settable from 0 to 100%
50.
%