59
“b” Function
A
B
Defaults
Func.
Code
Name
Description
Initial data
Units
Level of electronic
thermal
Set a level between 20% and 100% of the
rated inverter current.
Rated
current for
each
inverter
model
A
Level of electronic
thermal,
2
nd
motor
A
Electronic thermal
characteristic
Select from three curves, option codes:
Reduced torque
Constant torque
Free setting
01
Electronic thermal
characteristic,
2
nd
motor
01
Free setting
electronic thermal
~freq.1
Range is 0 to 400 Hz
0.0
Hz
Free setting
electronic thermal
~current1
Range is 0 to inverter rated current Amps
0.00
A
Free setting
electronic thermal
~freq.2
Range is 0 to 400 Hz
0.0
Hz
Free setting
electronic thermal
~current2
Range is 0 to inverter rated current Amps
0.00
A
Free setting
electronic thermal
~freq.3
Range is 0 to 400 Hz
0.0
Hz
Free setting
electronic thermal
~current3
Range is 0 to inverter rated current Amps
0.00
A
Overload
restriction
operation mode
Select the operation mode during overload
conditions, four options, option codes:
Disabled
Enabled for acceleration and constant
speed
Enabled for constant speed only
Enabled for acceleration and constant
speed, increase speed at regen.
01
Overload
restriction
operation mode,
2
nd
motor
01
Overload
restriction level
Sets the level of overload restriction, between
20 % and 150 % of the rated current of the
inverter, setting resolution is 1 % of rated
current
Rated
current
x 1.2
A
Overload
restriction level,
2
nd
motor
Rated
current
x 1.2
A
Deceleration rate
at overload
restriction
Sets the deceleration rate when inverter
detects overload, range is 0.1 to 3000.0,
resolution 0.1
1.0
s
Deceleration rate
at overload
restriction,
2
nd
motor
1.0
s