52
“A” Function
A
B
Defaults
Func.
Code
Name
Description
Initial data
Units
[O] input active range
start voltage
The starting point (offset) for
the active analog input range,
range is 0. to 100 %.
0.
%
[O] input active range
end voltage
The ending point (offset) for
the active analog input range,
range is 0. to 100.%
100.
%
[O] input start frequency
enable
Two options; select codes:
Use offset (
value)
Use 0 Hz
01
Analog input filter
Range n = 1 to 31,
1 to 30 :
×
2ms filter
31: 500ms fixed filter with
±
0.1 kHz hysteresis.
8.
Spl.
EzSQ function select
Select codes:
Disable
Activate by PRG terminal
Activate always
00
-
Multi-speed operation
selection
Select codes:
...Binary operation (16
speeds selectable with 4
terminals)
...Bit operation (8 speeds
selectable with 7
terminals)
00
-
Multi-speed freq. 0
Defines the first speed of a
multi-speed profile, range is
0.00 / start frequency to 400
Hz
6.0
Hz
Multi-speed freq. 0,
2
nd
motor
Defines the first speed of a
multi-speed profile or a 2nd
motor, range is 0.00 / start
frequency to 400 Hz
6.0
Hz
to
Multi-speed freq. 1 to
15
(for both motors)
Defines 15 more speeds,
range is 0.00 / start frequency
to 400 Hz.
=Speed 1 to
=Speed15
0.0
Hz
Jog frequency
Defines limited speed for jog,
range is from start frequency
to 9.99 Hz
6.00
Hz
Jog stop mode
Define how end of jog stops
the motor; six options:
Free-run stop (invalid
during run)
Controlled deceleration
(invalid during run)
DC braking to
stop(invalid during run)
Free-run stop (valid
during run)
Controlled deceleration
(valid during run)
DC braking to stop(valid
during run)
04