66
Intelligent Terminal Functions
“C” Function
A
B
Defaults
Func.
Code
Name
Description
Initial
data
Units
Input [1] function
Select input terminal [1] function, 56
options (see next section)
00
[FW]
Input [2] function
Select input terminal [2] function, 56
options (see next section)
01
[RV]
Input [3] function
[GS1 assignable]
Select input terminal [3] function, 56
options (see next section)
12
[EXT]
Input [4] function
[GS2 assignable]
Select input terminal [4] function, 56
options (see next section)
18
[RS]
Input [5] function
[PTC assignable]
Select input terminal [5] function, 56
options (see next section)
02
[CF1]
Input [6] function
Select input terminal [6] function, 56
options (see next section)
03
[CF2]
Input [7] function
Select input terminal [7] function, 56
options (see next section)
06
[JG]
Input [1] active state
Select logic conversion, two option codes:
normally open [NO]
normally closed [NC]
00
Input [2] active state
00
Input [3] active state
00
Input [4] active state
00
Input [5] active state
00
Input [6] active state
00
Input [7] active state
00
Output [11] function
[EDM assignable]
44 programmable functions available for
logic (discrete) outputs
(see next section)
00
[RUN]
Output [12] function
01
[FA1]
Alarm relay function
05
[AL]
[EO] terminal selection
(Pulse/PWM output)
11 programmable functions:
Output frequency (PWM)
Output current (PWM)
Output frequency (Pulse train)
Output voltage (PWM)
Input power (PWM)
Electronic thermal load ratio (PWM)
LAD frequency (PWM)
Output current (Pulse train)
Heat sink temperature (PWM)
General output (PWM)
Option(PWM)
07