35
Two Stage Acceleration and Deceleration
When terminal [2CH] is turned ON, the inverter
changes
the
rate
of
acceleration
and
deceleration from the initial settings (
and
) to use the second set of acceleration/
deceleration values. When the terminal is
turned OFF, the inverter is returned to the
original acceleration and deceleration time
(
acceleration
time
1,
and
deceleration time 1). Use
(acceleration
time 2) and
(deceleration time 2) to set
the second stage acceleration and deceleration
times.
In the graph shown above, the [2CH] becomes active during the initial acceleration. This
causes the inverter to switch from using acceleration 1 (
) to acceleration 2 (
).
Option
Code
Terminal
Symbol
Function Name
State
Description
2CH
Two-stage Accelera-
tion and
Deceleration
ON
Frequency output uses 2nd-stage acceleration and
deceleration values
OFF
Frequency output uses the initial acceleration 1 and
deceleration 1 values
Valid for inputs:
~
Example (requires input configuration see
page 66
):
See I/O specs on
page 23, 24.
Required settings
,
,
=
Notes:
Function
selects the method for second
stage acceleration. It must be set =
to select
the input terminal method in order for the [2CH]
terminal assignment to operate.
[2CH]
1
0
Output
frequency
t
[FW,RV]
1
0
Target
frequency
initial
second
2CH
7
6
5
4
3
2
1
L
P24
PLC