7-4
Chapter 7
Specifications
7.3 Common specifications (continue)
*6) The analogue voltage and analogue current monitor are estimated
outputs of the analogue meter connection. Maximum output value
might deviate slightly from 10V or 20mA by variation of the analogue
output circuit. If you want to change the characteristics, adjust the
Ao1 and Ao2 adjustment functions.
There is monitor data that cannot be part of the output.
*7) In order to enable the EMC filter, connect to the neutral grounding
supply. The leakage current may increase.
*8) Storage temperature is the temperature during transport.
*9) In accordance with the test methods of JIS C 60068-2-6:2010(IEC
60068-2-6:2007).
7.4 Current derating
For using with carrier frequency over 2.1 kHz, or when
changing load ratings to LD/VLD, refer to P1 user’s guide
section “20.4 Current derating table”.
*10) In case of utilization at an altitude of 1000m or more, take into
account that the atmospheric pressure is reduced by 1% for every
100m up. Apply 1% derating from the rated current by increasing
every 100m, and conduct an evaluation test. Contact us when using
above 2500m ambient.
*11) Insulation distance is in accordance with the UL and CE standards.
O
u
tp
u
t
Intelligent output
terminals
Transistor output terminal 5, 1a contact relay 1 point, 1c contact relay 1 point
RUN(While in run), FA1
~
5(Reached frequency signal), IRDY(Inverter ready), FWR(Forward rotation), RVR(Reverse rotation), FREF(panel
frequency reference), REF(panel motion operation), SETM(2nd-motor selected), OPO(Option-Output), AL(Alarm signal), MJA(Major
failure signal), OTQ(Over-torque), IP(Power loss), UV(Undervoltage), TRQ(Torque limited), IPS(Decel. Power loss), RNT(RUN time
exceeded), ONT(ON time exceeded), THM(Motor electronic thermal warning), THC(Electronic thermal warning), OH1(Motor temperature
increase), WAC(Capacitor life warning), WAF(Cooling-fan life warning), FR(Operation signal), OHF(heat sink overheat warning),
LOC/LOC2(Low-current indication signal), OL/OL2(Overload warning signal 1/2), BRK(Brake release)/BER(Brake error)/CON(Contactor
control), ZS(0Hz detection signal), DSE(Maximum speed deviation), PDD(Maximum position deviation), POK(Positioning completed),
PCMP(Pulse counter compare output), OD/OD2(Output deviation for PID control), FBV/FBV2(PID feedback comparison),
NDc(Communication disconnection), Ai1Dc/Ai2Dc/Ai3Dc(Analogue Ai1/Ai2/Ai3 disconnection), WCAi1/WCAi2/WCAi3(Window
comparator Ai1/Ai2/Ai3), LOG1
~
7(logical operation result 1
~
7), MO1
~
7(General-output 1
~
7), WFT(Trace waiting signal), TRA(Trace
running signal), LBK(Low battery of panel), OVS(Not assigned), the rest, is described in the contents of 4-35 “Output terminal function
list”.
Relay/
Alarm relay
(1a, 1c) function
EDM output terminal
Functional safety diagnostic output
Output terminal monitor
*6)
The data of the monitor can be selected by the parameter of the output.
EMC filter *7)
EMC filter can be enable (The filter exchange method can alter depending on the model)
PC external access
USB Micro-B
O
p
e
ra
ti
n
g
e
n
vi
ro
n
m
e
n
t
Ambient temperature
ND
-10
~
50°C
LD
-10
~
45°C
VLD
-10
~
40°C
Storage temperature *8)
-20
~
65°
Level of humidity
20
~
90%RH(No condensation allowed)
Vibration tolerance *9)
Model: up to P1-01240L(P1-220L)
up toP1-00620H(P1-220H)
5.9m/s
2
(0.6G), 10
~
55Hz
Model: more than P1-01530L(P1-300L)
More than P1-00770H(P1-300H)
2.94m/s
2
(0.3G), 10
~
55Hz
Installation place *10)
A maximum altitude of 1000m, without gases or dust.
Components life span
The life span of the main circuit smoothing capacitors is 10 years.
The life span of the cooling-fan is 10 years.
Conformity standars *11)
UL, cUL, CE marking, RCM, KC(Adquisition planned), EAC(Adquisition planned), NK(Adquisition planned),
Safety functions(STO:SIL3
、
Cat 3/PLe)(Adquisition planned)
Coating color
Black
Optional slots
3 ports
O
p
ti
o
n
a
l
b
o
a
rd
s
Input/ouput option
Analogue input/output option, relay output option
Communication option
Ethernet(TCP/IP)
、
EtherCAT
、
PROFIBUS DP
、
PROFINET
、
BACnet/IP
、
DeviceNet
Feedback option
Line driver input(RS422), push-pull input, resolver input
、アブソリュートエンコーダ用
Temperature detector
option
Optional temperature measuring sensor
Functional safety option
Functional safety option
Other optional components
Braking resistor, AC reactor, noise filter,operator cable, harmonics suppresion unit, noise filter, LCRfilter, analog panel, regenerative
braking unit, power regeneration converter, sine wave converter, various control application devices, PC software ProdriveNext, relay
expansion terminal board, SJ300/SJ700 conection board
Summary of Contents for P1-00041HFEF