Operation Setting and Examples of I/O Adjustment
Frequency source 2
3.5 Multispeed terminals command
•
While multispeed command is off, the speed command
will follow the parameter setting [AA101].
•
To use multispeed 0, select [AA101] = 07 frequency
source selection.
Frequency source
•
Change the frequency command by turning ON/OFF
from multispeed input terminals [CF1] and [CF2].
Parameter
Parameter
Details
Setting
data
[AA101]
Frequency setting from keypad
07
[FA-01]
*1)
Main speed source
0.00Hz
[Ab110]
*1)
Multispeed 0 setting 1
st
motor
([CF1]OFF/[CF2]OFF)
0.00Hz
[Ab-11]
*2)
Multispeed 1 setting
([CF1]ON/[CF2]OFF)
0.00Hz
[Ab-12]
*2)
Multispeed 2 setting
([CF1]OFF/[CF2]ON)
0.00Hz
[Ab-13]
*2)
Multispeed 3 setting
([CF1]ON/[CF2]ON)
0.00Hz
[CA-06]
The terminal 6 for [CF1]
001
[CA-07]
The terminal 7 for [CF2]
002
*1) While [AA101] = 07, a change made in either
[FA-01] or [Ab110] will be automatically reflected
in the other. When no change can be made or is
reflected in [FA-01], the operator keypad is not
specified as a command source by the terminal
function or [AA101].
*2) Set the frequency value for multispeed selection.
Run command source 2
3.6 Operate using FW/RV terminal
•
Select [AA111] = 00 [FW][RV] terminal from parameter
setting screen.
Run/stop command
•
Run or stop by turning either [FW] terminal or [RV]
terminal ON/OFF.
Parameter
Parameter
Details
Setting
data
[AA111]
Run using FW/RV terminal
00
[CA-09]
The terminal 9 for [FW]
001
[CA-08]
The terminal 8 for [RV]
002
Input terminals
5
6
[CF1]
7
[CF2]
8
COM
COM
Input terminals
7
8
[RV]
9
[FW]
A
COM