4-59
Chapter 4
For parameter configuration
[UA-01]
~
[UA-19]
■
Parameter mode (U code)
Password setting
Code/Name
Range (unit)
Initial value
UA-01
Password for display
0000
~
FFFF
0000
UA-02
Password for softlock
0000
~
FFFF
0000
・
When using the password, display and parameter mode
settings are locked
・
The inverter will be locked by password when setting
any value other than 0000. The password can be
cancelled by entering the set password. Please note
that, the restrictions will not be cancelled if you forget
the password.
Display mode of keypad
Code/Name
Range (unit)
Initial value
UA-10
Display
restriction selection
00(Full display)/
01(Function-specific display)/
02(User setting)/
03(Data comparison display)/
04(Monitor only)
00
・
Limit the displayed contents of the keypad.
・
For more information, refer to the User’s guide.
Accumulated power display adjustment/clear
Code/Name
Range (unit)
Initial value
UA-12
Accumulation output
power monitor clear
00(Disable)/
01(Clear)
00
UA-13
Display gain for
accumulation input power monitor
1
~
1000
1
UA-14
Accumulation output
power monitor clear
00(Disable)/
01(Clear)
00
UA-15
Display gain for
accumulation output power
monitor
1
~
1000
1
・
If [KHC] terminal is ON, the accumulated input power
can be clear.
・
If [OKHC] terminal is ON, the accumulated output power
can be clear.
Software lock operation settings
Code/Name
Range (unit)
Initial value
UA-16
Soft-Lock selection
00([SFT] terminal)/
01(Always enable)
00
UA-17
Soft-Lock target
selection
00(All data)/
01(All, except speed )
00
・
Sets the software lock operation.
Keypad copy function restriction
Code/Name
Range (unit)
Initial value
UA-18
Data R/W
selection
00(Not able to R/W)
01(Able to R/W)
00
・
Restricts the copy function(Read/Write).
Keypad low battery warning
Code/Name
Range (unit)
Initial
value
UA-19
Low battery warning
enable
01(Warning)/02(Error)
01
・
Sets operation for when keypad is low on battery.
[UA-20]
~
[UA-62]
Keypad communication lost operation
Code/Name
Range (unit)
Initial
value
UA-20
Operation
selection when keypad
communication is lost
00(Error)/
01(Error after deceleration stop)/
02(Ignore)/
03(Free-run)/
04(Deceleration stop)
02
User-parameter setting function
Code/Name
Range (unit)
Initial
value
UA-30
User-parameter auto setting
function enable
00(Disable)/
01(Enable)
00
UA-31
User-parameter 1 selection
no/
(parameter)
no
UA-32
User-parameter 2 selection
no
UA-33
User-parameter 3 selection
no
UA-34
User-parameter 4 selection
no
UA-35
User-parameter 5 selection
no
UA-36
User-parameter 6 selection
no
UA-37
User-parameter 7 selection
no
UA-38
User-parameter 8 selection
no
UA-39
User-parameter 9 selection
no
UA-40
User-parameter 10 selection
no
UA-41
User-parameter 11 selection
no
UA-42
User-parameter 12 selection
no
UA-43
User-parameter 13 selection
no
UA-44
User-parameter 14 selection
no
UA-45
User-parameter 15 selection
no
UA-46
User-parameter 16 selection
no
UA-47
User-parameter 17 selection
no
UA-48
User-parameter 18 selection
no
UA-49
User-parameter 19 selection
no
UA-50
User-parameter 20 selection
no
UA-51
User-parameter 21 selection
no
UA-52
User-parameter 22 selection
no
UA-53
User-parameter 23 selection
no
UA-54
User-parameter 24 selection
no
UA-55
User-parameter 25 selection
no
UA-56
User-parameter 26 selection
no
UA-57
User-parameter 27 selection
no
UA-58
User-parameter 28 selection
no
UA-59
User-parameter 29 selection
no
UA-60
User-parameter 30 selection
no
UA-61
User-parameter 31 selection
no
UA-62
User-parameter 32 selection
no
・
Sets the data displayed when [UA-10]=02.
Summary of Contents for P1-00041HFEF
Page 6: ...0 5 Contents Contents Memo ...
Page 42: ...2 26 Chapter 2 Installation and Wiring Memo ...
Page 129: ...Index Index 3 memo ...