7-2
Chapter 7
Specifications
400V class specifications
*1) The rated input current is the value when the drive is operated in the
rated output current. The value of the impedance at the supply side
changes due to the wiring, breaker, input reactor, etc.
*2) Make sure the following for Low Voltage Directive (LVD) compliant.
- Pollution degree 2
- Overvoltage category 3 (for 380
~
460Vac Input supply)
- Overvoltage category 2 (for over 460Vac Input supply)
*3) The power supply capacity is the value of the rated output current at
440V. Impedance at the supply side changes due to the wiring,
breaker, input reactor, etc.
*4) Is necessary to set the carrier frequency settings [bb101]/[bb201]
equal or greater than the (maximum output frequency x 10)Hz. For
induction motor IM, set the carrier frequency to 2 kHz or more
except V/f control. For synchronous motor (SM), permanent magnet
motor (PMM) set the carrier frequency to 8 kHz or more.
*5) The values for the sensorless vector control are assigned according
to the values in the ND rating of the Hitachi standard motor table.
Torque characteristics may vary by the control system and the use of
the motor.
*6) Usually is required an external regenerative braking unit. However,
with an optional built –in chopper braking ciruit and external
discharge resistor can eliminate a external regenerative unit. The
built-in chopper braking circuit is offered by order. In order to
purchase, contact to the nearest sales office.
*7) The key height of keypad are exclued from dimensions. When an
option is connected, the dept neccesary is increased. Refer to the
each optional instruction.
Model name(format)
P1-*****-L
00041 00054 00083 00126 00175 00250 00310 00400 00470 00620 00770 00930 01160 01470 01760 02130 02520 03160
ND standard capacity
P1-***L
007
015
022
037
055
075
110
150
185
220
300
370
450
550
750
900
1100 1320
Applicable motor
capacity (4
poles)(kW)
VLD
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
LD
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
ND
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
O
u
tp
u
t
Rated
output
current(A)
VLD
4.1
5.4
8.3
12.6
17.5
25.0
31.0
40.0
47.0
62.0
77.0
93.0
116
147
176
213
252
316
LD
3.1
4.8
6.7
11.1
16.0
22.0
29.0
37.0
43.0
57.0
70.0
85.0
105
135
160
195
230
290
ND
2.5
4.0
5.5
9.2
14.8
19.0
25.0
32.0
39.0
48.0
61.0
75.0
91.0
112
150
180
217
260
Overload
current
rating
VLD
110% 60sec / 120% 3sec
LD
120% 60sec / 150% 3sec
ND
150% 60sec / 200% 3sec
Rated output
voltage
Three-phase(3 wire)380
~
500V (Corresponding to the incoming voltage)
Rated
capac
ity
(kVA)
400V
VLD
2.8
3.7
5.8
8.7
12.1
17.3
21.5
27.7
32.6
43.0
53.3
64.4
80.4 101.8 121.9 147.6 174.6 218.9
LD
2.1
3.3
4.6
7.7
11.1
15.2
20.1
25.6
29.8
39.5
48.5
58.9
72.7
93.5 110.9 135.1 159.3 200.9
ND
1.7
2.8
3.8
6.4
10.3
13.2
17.3
22.2
27.0
33.3
42.3
52.0
63.0
77.6 103.9 124.7 150.3 180.1
500V
VLD
3.6
4.7
7.2
10.9
15.2
21.7
26.8
34.6
40.7
53.7
66.7
80.5 100.5 127.3 152.4 184.5 218.2 273.7
LD
2.7
4.2
5.8
9.6
13.9
19.1
25.1
32.0
37.2
49.4
60.6
73.6
90.9 116.9 138.6 168.9 199.2 251.1
ND
2.2
3.5
4.8
8.0
12.8
16.5
21.7
27.7
33.8
41.6
52.8
65.0
78.8
97.0 129.9 155.9 187.9 225.2
In
p
u
t
Rated input
current(A)
*1)
VLD
4.9
6.4
9.9
15.0
20.8
29.8
36.9
47.6
56.0
73.8
91.7 110.7 138.1 175.0 209.5 253.6 300.0 376.2
LD
3.7
5.7
8.0
13.2
19.0
26.2
34.5
44.0
51.2
67.9
83.3 101.2 125.0 160.7 190.5 232.1 273.8 345.2
ND
3.0
4.8
6.5
11.0
17.6
22.6
29.8
38.1
46.4
57.1
72.6
89.3 108.3 133.3 178.6 214.3 258.3 309.5
Rated input AC
voltage
*2)
Control power: Single-phase supply 380
~
500V (+10%, -15%)
Main circuit power supply: Three-phase(3 wire) 380
~
500V (+10%, -15%), 50Hz/60Hz(±5%)
Power
supply
capacity
(kVA)
*3)
VLD
3.7
4.9
7.5
11.4
15.9
22.7
28.1
36.3
42.6
56.3
69.9
84.4 105.2 133.4 159.7 193.2 228.6 286.7
LD
2.8
4.4
6.1
10.1
14.5
20.0
26.3
33.6
39.0
51.7
63.5
77.1
95.3 122.5 145.2 176.9 208.7 263.1
ND
2.3
3.6
5.0
8.3
13.4
17.2
22.7
29.0
35.4
43.5
55.3
68.0
82.6 101.6 136.1 163.3 196.9 235.9
Carrier
frequency
variation
*4)
VLD
0.5
~
10.0kHz
0.5
~
8.0kHz
LD
0.5
~
12.0kHz
0.5
~
8.0kHz
ND
0.5
~
16.0kHz
0.5
~
10.0kHz
Starting torque *5)
200%/0.3Hz
180%/0.3Hz
B
ra
k
in
g
Regenerative
Internal BRD circuit (external discharge resistor value)
*6)
Ext. regen. braking unit
Minimum
resistance value(Ω)
100
100
100
70
70
35
35
24
24
20
15
15
10
10
-
-
-
-
D
im
e
n
si
o
n
s
*
7
)
H(height)(mm)
255
255
255
255
260
260
260
390
390
390
540
550
550
550
700
700
740
740
W(width)(mm)
150
150
150
150
210
210
210
245
245
245
300
390
390
390
390
390
480
480
D(Depth)(mm)
140
140
140
140
170
170
170
190
190
190
195
250
250
250
270
270
270
270
Protective structure
IP20 – UL Open Type
IP00
Aprox. weight (kg)
4
4
4
4
7
7
7
16
16
16
22
30
30
30
55
55
70
70