4-53
Chapter 4
For parameter configuration
・
Sets the encoder to be input into the optional board,
and sets the motor gear ratio involved in the feedback
of the encoder
[ob-10]
~
[ob-16] [oE-01]
~
[oE-27]
P1-FB Pulse train input terminal setting
Code/Name
Range (unit)
Initial
value
Pu
ls
e
tr
ai
n
in
pu
t
(o
pt
io
n)
ob-10
Pulse train
detection object
selection (option)
00(Frequency reference)/
01(Pulse count)/
02(Speed feedback:
sensor-V/f)
00
ob-11
Mode selection of
pulse input (option)
00(90º-phase-shift)/
01(Forward/reverse operation
and direction of rotation)/
02(Forward/reverse operation
with pulse train)
00
Pu
ls
e
tr
ai
n
fr
eq
ue
nc
y
(o
pt
io
n)
ob-12
Pulse train
frequency scale
(option)
0.05
~
200.0(kHz)
50.0
ob-13
Pulse train filter
time constant
(option)
0.01
~
2.00(s)
0.10
ob-14
Pulse train
bias value (option)
-100.0
~
100.0(%)
0.0
ob-15
Pulse train
detection high limit
(option)
0.0
~
100.0(%)
100.
0
ob-16
Pulse train
detection low limit
(option)
0.0
~
100.0(%)
0.0
・
Set when using the option feedback.
・
For more information, refer to the user’s guide of the
corresponding option.
P1-FSOptional safety operation setting
Code/Name
Range(unit)
Initial
value
oC-01
Safety option input
display selection
00(Warning: with display)/
01(Warning: without display)
00
oC-10
SS1-A deceleration
time setting
0.00
~
3600.00(s)
30.00
oC-12
SLS-A deceleration time setting
0.00
~
3600.00(s)
30.00
oC-14
SLS-A Speed upper
limit: (Forward)
0.00
~
590.00(Hz)
0.00
oC-15
SLS-A Speed upper
limit: (Reverse)
0.00
~
590.00(Hz)
0.00
oC-16
SDI-A deceleration time setting
0.00
~
3600.00(s)
30.00
oC-18
SDI-A limited direction
00(Limit)
01(Invert)
00
oC-20
SS1-B deceleration
time setting
0.00
~
3600.00(s)
30.00
oC-22
SLS-B deceleration time setting
0.00
~
3600.00(s)
30.00
oC-24
SLS-B Speed upper
limit(Forward)
0.00
~
590.00(Hz)
0.00
oC-25
SLS-B Speed upper
limit(Reverse)
0.00
~
590.00(Hz)
0.00
oC-26
SDI-B deceleration time
0.00
~
3600.00(s)
30.00
oC-28
SDI-B deceleration time setting
00(Limit)
01(Invert)
00
・
For more detail refer to optional board instruction.
P1-AG Optional analog input setting
Code/Name
Range (unit)
Initial
value
[
A
i4
] t
er
m
in
al
oE-01
Filter time constant of [Ai4]
1
~
500(ms)
8
oE-03
Start value of [Ai4]
0.00
~
100.00(%)
0.00
oE-04
End value of [Ai4]
0.00
~
100.00(%)
100.00
oE-05
Start rate of [Ai4]
0.0
~
[oE-06](%)
0.0
oE-06
End rate of [Ai4]
[oE-05]
~
100.0(%)
100.0
oE-07
Start point selection of [Ai4]
[oE-05]
~
100.0(%)
100.0
[
A
i5
] t
er
m
in
al
oE-11
Filter time constant of [Ai5]
1
~
500(ms)
8
oE-13
Start value of [Ai5]
0.00
~
100.00(%)
0.00
oE-14
End value of [Ai5]
0.00
~
100.00(%)
100.00
oE-15
Start rate of [Ai5]
0.0
~
[oE-16](%)
0.0
oE-16
End rate of [Ai5]
[oE-15]
~
100.0(%)
100.0
oE-17
Start point selection of [Ai5]
00(Start value)/
01(0%)
01
[A
i6
] t
er
m
in
al
oE-21
Filter time constant of [Ai6]
1
~
500(ms)
8
oE-23
Start value of [Ai6]
0.00
~
100.00(%)
0.00
oE-24
End value of [Ai6]
0.00
~
100.00(%)
100.00
oE-25
Start rate of [Ai6]
0.0
~
[oE-26](%)
0.0
oE-26
End rate of [Ai6]
[oE-25]
~
100.0(%)
100.0
・
Regarding the adjustment method of the analog input,
please refer to the chapter 3 example of I/O terminals
adjustment.
[oE-28]
~
[oE-49]
P1-AG Optional analog input adjustment
Code/Name
Range (unit)
Initial
value
oE-28
[Ai4] Voltage/Current zero-bias
adjustment
-200.00
~
200.00(%)
0.00
oE-29
[Ai4] Voltage/Current gain
adjustment
-200.00
~
200.00(%)
100.00
oE-30
[Ai5] Voltage/Current zero-bias
adjustment
-200.00
~
200.00(%)
0.00
oE-31
[Ai5] Voltage/Current gain
adjustment
-200.00
~
200.00(%)
100.00
oE-32
[Ai6] Voltage zero-bias
adjustment
-200.00
~
200.00(%)
0.00
oE-33
[Ai6] Voltage gain adjustment
-200.00
~
200.00(%)
100.00
・
Regarding the adjustment method of the analog input,
please refer to the chapter 3 example of I/O terminals
adjustment.