4-54
Chapter 4
For parameter configuration
[oE-35]
~
[oE-49]
P1-AG Window comparators output condition
Code/Name
Range (unit)
Initial
value
W
in
do
w
C
om
pa
ra
to
r
oE-35
Window comparator for
[Ai4] higher level
-100
~
100(%)
100
oE-36
Window comparator for
[Ai4] lower level
-100
~
100(%)
-100
oE-37
Window comparator for
[Ai4] hysterisis width
0
~
10(%)
0
oE-38
Window comparator for
[Ai5] higher level
0
~
100(%)
100
oE-39
Window compareter for
[Ai5] lower level
0
~
100(%)
0
oE-40
Window compareter for
[Ai5] hysterisis width
0
~
10(%)
0
oE-41
Window compareter for
[Ai6] higher level
0
~
100(%)
100
oE-42
Window compareter for
[Ai6] lower level
0
~
100(%)
0
oE-43
Window compareter for
[Ai6] hysterisis width
0
~
10(%)
0
D
is
co
nn
ec
tio
n
de
te
ct
io
n
oE-44
Operation level at [AI4]
disconnection
-100
~
100(%)
0
oE-45
Operation level
selection at [Ai4] disconnection
00(Disable)/
01(Out of range)/
02(Inside range)
00
oE-46
Operation level at [AI5]
disconnection
0
~
100(%)
0
oE-47
Operation level
selection at [Ai5] disconnection
00(Disable)/
01(Out of range)/
02(Inside range)
00
oE-48
Operation level at [AI5]
disconnection
0
~
100(%)
0
oE-49
Operation level
selection at [Ai5] disconnection
00(Disable)/
01(Out of range)/
02(Inside range)
00
・
Outputs a signal whenever the analog input value is
within or out of range.
・
As for disconnection detection, if it is in the case of
within or out of the range, a value can be set for the
operation command.
[oE-50]
~
[oE-70]
P1-AG Optional analog output adjustment
Code/Name
Range (unit)
Initial
value
oE-50
[Ao3] monitor output
selection]
Set monitor code
dA-01
oE-51
[Ao4] monitor output
selection
dA-01
oE-52
[Ao5] monitor output
selection
dA-01
oE-56
Filter time constant of [Ao3]
monitor[Ao3] Data type selection
1
~
500(ms)
10
oE-57
[Ao3] Data type selection
00(Absolute value)/
01(Signed value)
00
oE-58
[Ao3] monitor bias
adjustment
-100.0
~
100.0(%)
100.0
oE-59
[Ao3] monitor gain
adjustment
-1000.0
~
1000.0(%)
100.0
oE-60
Output level setting at
[Ao3] monitor adjust mode
0.0
~
300.0(%)
100.0
oE-61
Filter time constant of
[Ao4] monitor
1
~
500(ms)
10
oE-62
[Ao4] Data type selection
00(Absolute value)/
01(Signed value)
00
oE-63
[Ao4] monitor bias
adjustment
-100.0
~
100.0(%)
100.0
oE-64
[Ao4] monitor gain
adjustment
-1000.0
~
1000.0(%)
100.0
oE-65
Output level setting at
[Ao4] monitor adjust mode
0.0
~
300.0(%)
100.0
oE-66
Filter time constant of [Ao5]
monitor
1
~
500(ms)
10
oE-67
[Ao5] Data type selection
00(Absolute value)/
01(Signed value)
00
oE-68
[Ao5] monitor bias
adjustment
-100.0
~
100.0(%)
100.0
oE-69
[Ao5] monitor gain
adjustment
-1000.0
~
1000.0(%)
100.0
oE-70
Output level setting at
[Ao5] monitor adjust mode
0.0
~
300.0(%)
100.0
・
Regarding the adjustment method of the analog output,
please refer to the chapter 3 example of I/O terminals
adjustment.