![Hitachi HUS VM User And Reference Manual Download Page 77](http://html.mh-extra.com/html/hitachi/hus-vm/hus-vm_user-and-reference-manual_145969077.webp)
•
Logs when the abnormal operation
Aug 24 12:24:27 raidmanager raidcom: PID:06857 COMMAND ERROR :
EUserID for HORC : root(0) Fri Aug 24 12:24:19 2012
Aug 24 12:24:27 raidmanager raidcom: PID:06857 CMDLINE : raidcom
get command_status
Aug 24 12:24:27 raidmanager raidcom: PID:06857 [raidcom] User
for Serial#[64568] : user1234
Aug 24 12:24:27 raidmanager raidcom: PID:06857 [raidcom] User
authentication has failed on Serial#(64568).
Aug 24 12:24:27 raidmanager raidcom: PID:06857 [raidcom]
[EX_ENAUTH] Authentication failed with User
Aug 24 12:24:27 raidmanager raidcom: PID:06857 [raidcom]
[exit(202)]
User-created files
CCI supports scripting to provide automated and unattended copy operations.
A CCI script contains a list of CCI commands that describes a series of
TrueCopy and/or ShadowImage operations. The scripted commands for
UNIX-based platforms are defined in a shell script file. The scripted
commands for Windows-based platforms are defined in a text file. The host
reads the script file and sends the commands to the command device to
execute the TrueCopy/ShadowImage operations automatically.
The CCI scripts are:
•
HORCM startup script (horcmstart.sh, horcmstart.exe).
A script that
starts HORCM (/etc/horcmgr), sets environment variables as needed (for
example, HORCM_CONF, HORCM_LOG, HORCM_LOGS), and starts
HORCM.
•
HORCM shutdown script. (horcmshutdown.sh,
horcmshutdown.exe):
A script for stopping the HORCM (/etc/horcmgr).
•
HA control script.
A script for executing takeover processing
automatically when the cluster manager (CM) detects a server error.
When constructing the HORCM environment, the system administrator should
make a copy of the
horcm.conf
file. The copied file should be set according
to the system environment and registered as the following file (* is the
instance number):
UNIX systems:
/etc/horcm.conf
or
/etc/horcm*.conf
Windows systems:
%windir%\horcm.conf
or
%windir%\horcm*.conf
User environment variable
When HORCM or command is invoked, environment variable can be specified.
CCI software environment
2-49
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...