Problem
Recommended action
HORCM_LOG (the default setting: /horcm/log/), and then contact
Hitachi Data Systems customer support.
The following
messages are
output to the
standard error
output with
every command
I/O:
"/usr/lib/
dld.sl: Can't
shl_load() a
library
containing
Thread Local
Storage: /usr/
lib/libcl.sl"
"/usr/lib/
dld.sl: Exec
format error"
These messages are output if the path for the PA-RISC version shared
library (libcl.sl) is not set when you use CCI on HP-UX (IA64).
Set the path of the libcl.sl to the LD_PRELOAD environment variable.
Example:
# export LD_PRELOAD=/
path
/libcl.sl
Enter the absolute path for specifying the directory where libcl.sl is
stored into
path
.
When you
attempt to
remove RM
Shadow Copy
Provider, the
installer displays
a message
indicating that a
file cannot be
deleted because
it is used by
another
program.
Perform the following steps to delete the file:
1
.
Check the information about the program that is using the file
indicated by the installer.
2
.
Stop the removal of RM Shadow Copy Provider.
3
.
Close the program you found out in step 1.
4
.
Try to remove RM Shadow Copy Provider again.
5
.
Repeat steps 1 through 4 until you can remove RM Shadow Copy
Provider successfully.
Operational notes and restrictions for CCI operations
For maintenance of volumes used by CCI and the HDS features it supports, if
a volume failure occurs, it is important to find the failure in the paired
volumes, recover the volumes, and continue operation on the original
system. When a CCI (HORCM) or HDS feature failure is detected, please
collect the data in the error log file and trace data (all files in HORCM_LOG
directory), and report the failure to your HDS representative.
Items
Notes and restrictions
Startup restrictions When the server starts up, sometimes a volume group (VG) is
activated by the LVM, or a file system is mounted automatically,
and the host writes to the S-VOL. When this happens, if the S-VOL
does not permit writing, data cannot be written and the operation
fails. To avoid this failure, change the S-VOL to PSUS (R/W enable)
or to the SMPL state and restart the server.
Troubleshooting
9-3
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...