raidcom delete snapshot
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
•
The control table for Thin Image is depleted.
CMDRJE
Executing
2E11
2206
You do not have the operation authority to operate
the target resource group.
Specify the resource group that is allocated to the
user group as the operation target, or set the
operation authority to the user group in order to
operate the target resource group.
CMDRJE
Executing
2E11
8003
The operation cannot be performed because
power-off is in progress.
CMDRJE
Executing
2E11
9704
The operation cannot be performed because a pair
exists under the specified pair.
CMDRJE
Executing
2E11
9706
The operation cannot be performed because the
specified volume is not a root volume of a pair with
the cascade or clone attribute, or the volume is an
S-VOL in another snapshot tree.
CMDRJE
Executing
2E20
0000
The specified LDEV is not defined.
CMDRJE
Executing
2E20
0008
The command ends abnormally because an
unmounted volume is specified as the P-VOL of a
Thin Image pair or a Copy-on-Write Snapshot pair.
CMDRJE
Executing
2E20
0009
The command ends abnormally because the
blocked volume is specified as the P-VOL of a Thin
Image pair or a Copy-on-Write Snapshot pair.
CMDRJE
Executing
2E21
8107
The command ends abnormally because the shared
memory (FC, TPF, or Extension2) is not added for
necessary capacity or maintenance work is being
performed.
CMDRJE
Executing
2E21
8108
The shared memory for Thin Image or Copy-on-
Write Snapshot is not installed.
CMDRJE
Executing
2E21
9306
The virutal LDEV ID for a virtual storage machine is
not defined on the specified LDEV.
CMDRJE
Executing
2E21
930A
The virtual storage machine with the specified
serial number is not found.
CMDRJE
Executing
2EC6
FEEC
An internal error occurred. Call Hitachi Data
Systems customer support.
CMDRJE
Executing
B980
B903
The command was rejected because the selected
resource belongs to NAS_Platform_System_RSG.
Troubleshooting
9-101
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...