Error
code
Error
message
Condition
Recommended action
Returne
d Value
EX_ATTD
BG
Can't be
attached
to a
Debug
layer
Failed to communicate with
HORCM, or cannot make a
log directory file.
Verify that HORCM is running by using
UNIX commands [ps - ef | grep horcm].
250
EX_INVN
AM
Invalid
name of
option
The name specified in an
argument of an option is not
appropriate.
Please designate the correct name using
the -h option.
249
EX_OPTI
NV
A
specified
option is
invalid
Detected contradiction in
information that RAID
reported.
Contact Hitachi Data Systems customer
support.
248
EX_ENOE
NT
No such
device or
group
The designated device or
group name does not exist in
the configuration definition
file.
Verify the device or group name and
add it to the configuration definition file
of the remote and local hosts.
247
EX_ENOD
EV
No such
device
The designated device name
does not exist in the
configuration definition file.
Verify the device name and add it to the
configuration definition file of the
remote and local hosts.
246
EX_ENOU
NT
No such
RAID unit
The designated RAID unit ID
does not exist in the
configuration definition file.
Verify the RAID unit ID and add it to the
configuration definition file of the
remote and local hosts.
219
EX_ENQS
ER
Unmatche
d Serial#
vs RAID
unitID
The group designated by
ShadowImage paircreate
does not have the same
RAID unit, or the unitID is
not identical to the unit ID in
the same RAID serial#
(Seq#).
Confirm the serial# (Seq#) of the
storage system using the
pairdisplay
command, or confirm that the serial#
(Seq#) and the unit ID of storage
system are the same among hosts using
the
raidqry -r
command.
218
EX_ENOM
EM
Not
enough
core
Insufficient memory exists.
Increase the virtual memory capacity of
the system, or close any unnecessary
programs and/or daemon processes.
245
EW_ENES
CR
Cannot
execute
script file
The script file specified by
the -zt option cannot be
performed.
Confirm the execution right, permission
the extension, the execution path of the
script file.
131
EX_ERAN
GE
Result too
large
Your entry is one of the
following statuses.
•
The value was entered
beyond the maximum.
•
The result value is
beyond the maximum.
•
The unit you set is
invalid.
Refer to the error message, and
designate an appropriate value or
confirm whether you specified the unit
correctly.
244
EX_ENAM
LG
File name
too long
Undefined error.
Contact Hitachi Data Systems customer
support.
243
Troubleshooting
9-9
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...