![Hitachi HUS VM User And Reference Manual Download Page 456](http://html.mh-extra.com/html/hitachi/hus-vm/hus-vm_user-and-reference-manual_145969456.webp)
Table 9-69 SSB codes returned by raidcom modify port -port_speed
raidcom modify port -port_speed
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
CMDRJE
Executing
B955
01C1
The specified LDEV is used as a quorum disk.
CMDRJE
Executing
B955
020F
The specified LDEV is not installed.
CMDRJE
Executing
B955
0304
An LU path or a logical path has been defined.
CMDRJE
Executing
B955
0404
An LU path or a logical path has been defined.
CMDRJE
Executing
B955
040F
An internal error occurred.
CMDRJE
Executing
B955
044C
The specified AL-PA is invalid.
CMDRJE
Executing
B955
054E
The specified topology is invalid.
CMDRJE
Executing
B955
05A6
The other than "fabric on" cannot be specified
when specifying a topology of the package for
Fibre Channel over Ethernet.
CMDRJE
Executing
B955
05A7
The other than "P-to-P (point to point)" cannot be
specified when specifying a topology of the
package for Fibre Channel over Ethernet.
CMDRJE
Executing
B955
060F
The specified LDEV is not installed.
CMDRJE
Executing
B955
06C0
The specified LDEV is being used as a volume of a
GAD pair.
CMDRJE
Executing
B955
06C1
The specified LDEV is used as a quorum disk.
CMDRJE
Executing
B955
06C2
The specified LDEV is used for a TrueCopy pair or a
Universal Replicator pair.
CMDRJE
Executing
B955
1039
The command device being used at the local CCI
exists under the port.
CMDRJE
Executing
B955
104F
The program product is not installed.
CMDRJE
Executing
B955
113D
Invalid host speed is set for 4Gbps fibre adapter.
The available host speeds are AUTO, 1G, 2G, and
4G only.
CMDRJE
Executing
B955
113E
Invalid host speed is set for the specified fibre
adapter.
CMDRJE
Executing
B955
113F
Invalid host speed is set for 8Gbps fibre adapter.
The available host speeds are AUTO, 2G, 4G, and
8G only.
CMDRJE
Executing
B955
11A5
The other than "10G" cannot be specified when
specifying a host speed of the package for Fibre
Channel over Ethernet.
CMDRJE
Executing
B955
11AE
Invalid host speed is set for 16Gbps fibre adapter.
The available host speeds are AUTO, 2G, 4G, and
8G only.
CMDRJE
Executing
B955
12AF
The combination of the specified host speed and
the topology FC-AL set for the fibre channel
9-132
Troubleshooting
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...