![Hitachi HUS VM User And Reference Manual Download Page 395](http://html.mh-extra.com/html/hitachi/hus-vm/hus-vm_user-and-reference-manual_145969395.webp)
raidcom add lun
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
CMDRJE
Executing
B958
0639
The command device cannot be operated because
it is used at the local CCI.
CMDRJE
Executing
B958
064A
A command device cannot be set because LDEV is
other than the OPEN volume.
CMDRJE
Executing
B958
065D
The specified LDEV is not installed.
CMDRJE
Executing
B958
0679
A command device cannot be set because LDEV is
the virtual volume of Thin Image or Copy-on-Write
Snapshot.
CMDRJE
Executing
B958
06C0
The specified LDEV is being used as a volume of a
GAD pair.
CMDRJE
Executing
B958
06C1
The specified LDEV is used as a quorum disk.
CMDRJE
Executing
B958
06C2
The specified LDEV is used for a TrueCopy pair or a
Universal Replicator pair.
CMDRJE
Executing
B958
0927
The command cannot be operated because the
virtual LDEV is not defined yet.
CMDRJE
Executing
B958
0944
The value of LUN exceeds the maximum.
CMDRJE
Executing
B958
0945
The value of LDEV exceeds the maximum.
CMDRJE
Executing
B958
0947
Another LDEV is already mapped to the specified
LUN.
CMDRJE
Executing
B958
0956
The value of Host group ID exceeds the maximum.
CMDRJE
Executing
B958
0957
The program product is not installed.
CMDRJE
Executing
B958
0959
The specified host group is not installed.
CMDRJE
Executing
B958
095D
An invalid LDEV exists in the specified LDEVs.
CMDRJE
Executing
B958
098C
The multiple LDEV cannot be specified.
CMDRJE
Executing
B958
098D
When the host mode option 60 is set, the LU path
of LUN0 cannot be set or released.
CMDRJE
Executing
B958
0994
An invalid LDEV exists in the specified LDEVs.
CMDRJE
Executing
B958
0996
The LU path cannot be added because the virtual
LDEV ID of the specified volume was deleted.
CMDRJE
Executing
B958
099C
The number of paths exceeds the maximum.
CMDRJE
Executing
B958
099D
Only one path is set for NAS Platform (User LU).
CMDRJE
Executing
B958
099E
Both the port number and the host group ID are
specified.
CMDRJE
Executing
B958
099F
The specified port is not mounted.
CMDRJE
Executing
B958
09F8
The LU path cannot be set because the specified
LDEV is being deleted.
Troubleshooting
9-71
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...