raidcom unmap snapshot
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
CMDRJE
Executing
2E10
0060
The command ends abnormally because the
specified S-VOL is not assigned to a Thin Image
pair.
CMDRJE
Executing
2E10
0061
The specified volume cannot be used for the Thin
Image pair operation because the virtual LDEV ID
is deleted.
CMDRJE
Executing
2E10
0204
The operation failed because the specified LDEV
which is holding the attribute of SLU is bind to the
LDEV which is holding the attribute of ALU.
CMDRJE
Executing
2E10
9709
The command ends abnormally because the
specified Thin Image pair is not exist.
CMDRJE
Executing
2E10
970C
The command ends abnormally because the
specified Thin Image pair is not assigned to an S-
VOL.
CMDRJE
Executing
2E10
9710
The clone attribute of the specified Thin Image pair
is enabled.
CMDRJE
Executing
2E10
9711
The operation cannot be performed because the S-
VOL is the node volume.
CMDRJE
Executing
2E10
9713
The operation cannot be performed because the
snapshot tree is being deleted.
CMDRJE
Executing
2E11
800F
The operation failed because multiple versions of
DKCMAIN microcode are included.
CMDRJE
Executing
2E20
0000
The specified LDEV is not defined.
CMDRJE
Executing
2E20
0008
The command ends abnormally because an
unmounted volume is specified as the P-VOL of a
Thin Image pair or a Copy-on-Write Snapshot pair.
CMDRJE
Executing
2E20
000B
The command ends abnormally because an
unmounted volume is specified as the S-VOL of a
Thin Image pair or a Copy-on-Write Snapshot pair.
CMDRJE
Executing
2E20
000C
The command ends abnormally because the
blocked volume is specified as the S-VOL of a Thin
Image pair or a Copy-on-Write Snapshot pair.
CMDRJE
Executing
2E21
8107
The command ends abnormally because the shared
memory (FC, TPF, or Extension1) is not added for
necessary capacity or maintenance work is being
performed.
CMDRJE
Executing
2E21
8108
The shared memory for Thin Image or Copy-on-
Write Snapshot is not installed.
CMDRJE
Executing
2E21
9010
The program product is not installed.
CMDRJE
Executing
2E21
9306
The virutal LDEV ID for a virtual storage machine is
not defined on the specified LDEV.
Troubleshooting
9-111
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...