Chapter 4 Wiring
You can connect the RS-485 terminal with the RS-485 card reader, connect the NC and COM
terminal with the door lock, connect the SENSOR terminal with the door contact, the BTN/GND
terminal with the exit button, connect the alarm output and input terminal with the alarm output/
input devices, and connect the Wiegand terminal with the Wiegand card reader or the access
controller.
If connect the WIEGAND terminal with the access controller, the face recognition terminal can
transmit the authentication information to the access controller and the access controller can
judge whether to open the door or not.
Note
●
If cable size is 18 AWG, you should use a 12 V power supply. And the distance between the
power supply and the device should be no more than 20 m.
●
If the cable size is 15 AWG, you should use a 12 V power supply. And the distance between the
power supply and the device should be no more than 30 m.
●
If the cable size is 12 AWG, you should use a 12 V power supply. And the distance between the
power supply and the device should be no more than 40 m.
4.1 Terminal Description
The terminals contains power input, alarm input, alarm output, RS-485, Wiegand output, and door
lock.
The terminal's diagram is as follows: