9.14.12 Set Access Control Parameters
Steps
1. On the Device for Management page, click → Others → Access Control Parameters to enter
the Access Control Parameters tab.
2. Check the checkbox to enable the function.
Audio Prompt (Voice Prompt)
If you enable this function, the voice prompt is enabled in the device. You can hear the voice
prompt when operating in the device.
Upload Pictures after Capturing
If you enable this function, the captured pictures will be sent to the client software.
Save Captured Pictures
If you enable this function, the captured pictures will be saved.
Temperature Measurement Only
When enabling the function, the device will not authenticate the permissions, but only take
the temperature. When disabling the function, the device will authenticate the permissions
and at the same time take the temperature.
Capture White Light Picture
When enabling the function, the pictures captured by the white light camera will be uploaded
to the platform. If disabling the function, the device will only upload pictures captured by
thermographic camera to the platform.
Door Not Open When Detecting Abnormal Temperature
When enabling the function, the door will not open when the detected temperature is higher
or lower than the configured temperature threshold. By default, the temperature is enabled.
Must Wear Face Mask
After enabling this function, the authenticated person must wear a face mask, otherwise the
authentication will be failed.
Over-Temperature Alarm
Edit the threshold according to actual situation. If the detected temperature is higher than
the configured parameters, an alarm will be triggered. The value should be between 35.1
℃
and 44.9
℃
.
3. Click Save.
9.14.13 Set Face Recognition Terminal Parameters
Click Maintenance and Management → Device to enter the device list.
Press CTRL and click to enter the remote configuration page.
DS-K1TA70 Series Face Recognition Terminal User Manual