Note
If you change the peripheral, and after you save the device parameters, the device will reboot
automatically.
Set Privacy Parameters
Set the event storage type, picture upload and storage parameters, and the picture clearing
parameters.
Go to Configuration → Access Control → Privacy .
Event Storage Settings
Select a method to delete the event. You can select from Delete Old Events Periodically, Delete
Old Events by Specified Time, or Overwriting.
Delete Old Events Periodically
Drag the block or enter number to set the period for event deleting. All events will be deleted
according to the configured time duration.
Delete Old Events by Specified Time
Set a time and all events will be deleted on the configured time.
Overwriting
The earliest 5% events will be deleted when the system detects the stored events has been over
95% of the full space.
Authentication Settings
Display Authentication Result
You can check Face Picture, Name, Employee ID and Temperature, to display the authentication
result.
Picture Uploading and Storage
Upload Captured Picture When Authenticating
Upload the pictures captured when authenticating to the platform automatically.
Save Captured Picture When Authenticating
If you enable this function, you can save the picture when authenticating to the device.
Save Registered Picture
The registered face picture will be saved to the system if you enable the function.
Upload Picture After Linked Capture
Upload the pictures captured by linked camera to the platform automatically.
Save Pictures After Linked Capture
DS-K1TA70 Series Face Recognition Terminal User Manual