Configure SIP Parameters
Set the device's IP address and the SIP server's IP address. After setting the parameters, you can
communicate among the access control device, door station, indoor station, main station, and the
platform.
Note
Only the access control device and other devices or systems (such as door station, indoor station,
main station, platform) are in the same IP segment, the two-way audio can be performed.
Go to Configuration → Access Control → Linked Network Settings .
Set the main station's IP address and SIP server's IP address.
Click Save.
Set RS-485 Parameters
You can set the RS-485 parameters including the peripheral, address, baud rate, etc.
Click Configuration → Access Control → RS-485 Settings .
Click Save to save the settings after the configuration.
No.
Set the RS-485 No.
Peripheral Type
Select a peripheral from the drop-down list according the actual situation. You can select from
Card Reader, Extension Module, Access Controller, or Disable.
Note
After the peripheral is changed and saved, the device will reboot automatically.
RS-485 Address
Set the RS-485 Address according to your actual needs.
Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
Baud Rate
The baud rate when the devices are communicating via the RS-485 protocol.