Programming Q Parameters | Principle and overview of functions
10
368
HEIDENHAIN | TNC 620 | Conversational Programming User's Manual | 10/2017
Programming notes
You can mix Q parameters and numerical values within an
NC program.
Q parameters can be assigned numerical values between
-999 999 999 and +999 999 999. The input range is limited to
16 digits, of which 9 may be before the decimal point. Internally the
control calculates numbers up to a value of 10
10
.
You can assign a maximum of 255 characters to
QS
parameters.
The control automatically assigns some Q and QS
parameters the same data, e.g., the Q parameter
Q108
is automatically assigned the current tool radius.
The control saves numerical values internally in a
binary number format (standard IEEE 754). Due
to the standardized format used, the control does
not represent some decimal numbers with a binary
number that is 100% exact (round-off error). If you use
calculated Q parameter contents for jump commands
or positioning moves, then you must take this fact into
consideration.
You can reset Q parameters to the status
Undefined
. If a position
is programmed with a Q parameter that is undefined, the control
ignores this movement.
Summary of Contents for TNC 620 E
Page 4: ......
Page 5: ...Fundamentals...
Page 34: ...Contents 34 HEIDENHAIN TNC 620 Conversational Programming User s Manual 10 2017...
Page 63: ...1 First Steps with the TNC 620...
Page 86: ......
Page 87: ...2 Introduction...
Page 123: ...3 Operating the Touchscreen...
Page 139: ...4 Fundamentals File Management...
Page 199: ...5 Programming Aids...
Page 228: ......
Page 229: ...6 Tools...
Page 271: ...7 Programming Contours...
Page 323: ...8 Data Transfer from CAD Files...
Page 344: ......
Page 345: ...9 Subprograms and Program Section Repeats...
Page 364: ......
Page 365: ...10 Programming Q Parameters...
Page 467: ...11 Miscellaneous Functions...
Page 489: ...12 Special Functions...
Page 532: ......
Page 533: ...13 Multiple Axis Machining...
Page 596: ......
Page 597: ...14 Pallet Management...
Page 610: ......
Page 611: ...15 Batch Process Manager...
Page 619: ...16 Manual Operation and Setup...
Page 693: ...17 Positioning with Manual Data Input...
Page 698: ......
Page 699: ...18 Test Run and Program Run...
Page 737: ...19 MOD Functions...
Page 774: ......
Page 775: ...20 Tables and Overviews...