SupervisorMode
WTX120
A4500-1.1
HBM: public
93
10.2.9
Optimization
When Optimization is active (parameter P1 > 0), the coarse flow and fine flow
phases are optimized by the sensor electronics. The minimum fine flow weight
(FFM) ensures compliance with the tolerances. This limit prevents the fine flow
component being minimized still further by increasing the coarse flow compo
nent.
Menu
Key
Function/Secondary selection
Optimization
0
Optimization deactivated
1
Highest degree of optimization,
correction factor 1
2
Medium degree of optimization,
correction factor 0.5
3
Lowest degree of optimization,
correction factor 0.25
Significance of parameter P1
A correction factor of 1 means that 100% of the difference between the actual
and target weight - i.e., between too much and too little fill material - is calcu
lated into the next cut‐off point. With a correction factor of 0.5, only 50% of the
difference is included in the calculation.
10.2.10
Re-Dosing
If the previously measured actual value is below the lower tolerance limit, re-
dosing is carried out. When optimization is active (parameter P1 > 0), the result
of a re-dosing operation does not change the cut-off points.
Re-dosing is carried out with a fine flow.
Summary of Contents for WTX120
Page 1: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 3: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 184: ...Service password 182 A4500 1 1 HBM public WTX120 ...
Page 185: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 366: ...Service Passwort 182 A4500 1 1 HBM public WTX120 ...
Page 367: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 549: ...Mot de passe de service WTX120 A4500 1 1 HBM public 183 ...