SupervisorMode
WTX120
A4500-1.1
HBM: public
111
10.2.35
Stabilization time (Stabilizat.(s))
After the fill flow phase and residual flow phase comes the stabilization time.
If standstill recognition (MTD) is active, checkweighing is carried out after
standstill, but within the stabilization time. Otherwise checkweighing is started
immediately.
If there is no standstill within the stabilization time the actual weight is mea
sured in any case once the stabilization time expires.
10.2.36
Emptying time (Empt.time(s))
By setting parameter P1 > 0 you activate the emptying time. Emptying starts
immediately after checkweighing. Then the preconfigured control output
(Empty) is activated to carry out emptying, and is automatically switched to the
gross measurement value. Emptying is regarded as complete when the gross
weight in emptying mode is below the empty weight or when the emptying time
(in both emptying modes) is exceeded. If the emptying time is exceeded, emp
tying ends, regardless of whether the scale is empty or not. When emptying is
complete, the end of the filling process is indicated by the Finished signal (
see
also chapter 10.2.15 „Empty weight“
).
10.2.37
Number of dosing operations (No. of dosing)
With each dosing result the number of dosing operations is increased by 1.
The Reset command clears the counter. The counter stops at 65.535 if it is not
reset. The total weight
,
the mean value of the dosing results and the number of
dosing operations are updated simultaneously.
Summary of Contents for WTX120
Page 1: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 3: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 184: ...Service password 182 A4500 1 1 HBM public WTX120 ...
Page 185: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 366: ...Service Passwort 182 A4500 1 1 HBM public WTX120 ...
Page 367: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 549: ...Mot de passe de service WTX120 A4500 1 1 HBM public 183 ...