PLC link
152
A4500-1.1
HBM: public
WTX120
13
PLC link
The weighing module is controlled by the PLC (control
system) completely via Profibus DP, Profinet or Ethernet/
IP.
Values are transferred from the terminal and the PLC by
exchanging data words.
13.1 Number format of the input and
output words (16-bit)
Information
The bit address is organized byte-wise in the I/O range of
the PLC, meaning EW0 is distributed across bytes
EB0 and EB1, with the less significant bits in EB1!
Number format as 16-digit dual numbers or as bit pattern:
Word
no.
n
Byte no.
N (High byte)
N+1 (Low byte)
Bit no.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Signi-
ficance
2
15
2
14
2
13
2
12
2
11
2
10
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
The value range for Int16 (16-bit integer) is
-32768 to 32765.
The value range for UInt16 (16-bit unsigned integer) is
0 to 65535.
Summary of Contents for WTX120
Page 1: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 3: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 184: ...Service password 182 A4500 1 1 HBM public WTX120 ...
Page 185: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 366: ...Service Passwort 182 A4500 1 1 HBM public WTX120 ...
Page 367: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 549: ...Mot de passe de service WTX120 A4500 1 1 HBM public 183 ...