![HBM WTX120 Operating Manual Download Page 25](http://html1.mh-extra.com/html/hbm/wtx120/wtx120_operating-manual_2111754025.webp)
Installation
WTX120
A4500-1.1
HBM: public
23
KL1 6-wire
1
–EXC
–Excitation
2
–SEN
–Sense
3
–SIG
–Signal
4
+SIG
+Signal
5
+SEN
+Sense
6
+EXC
+Excitation
7
SHLD
SHIELD
Tab. 5.1
Connection of a 6-wire analog load cell to the
WTX120
Tip
Use a suitable terminal box, such as type VKK1-4 or
VKK2-8 from HBM, to wire multiple load cells.
To operate load cells without sense wires (4-wire mode),
jumpers must be fitted on terminal KL1 between pins 1
and 2 and 5 and 6.
KL1 4-wire
1/2
–EXC / –SEN
–Excitation
3
–SIG
–Signal
4
+SIG
+Signal
5/6
+EXC / +SEN
+Excitation
7
SHLD
SHIELD
Tab. 5.2
Connection of a 4-wire analog load cell to the
WTX120