![HBM WTX120 Operating Manual Download Page 179](http://html1.mh-extra.com/html/hbm/wtx120/wtx120_operating-manual_2111754179.webp)
Troubleshooting
WTX120
A4500-1.1
HBM: public
177
Remedy
Possible causes
Display error mes
sage
Powerup Out of
Range
Over/under power-up zero
setting range. This message
appears immediately after
power-up if the scale is
loaded with a weight greater
than the set power-up zero
range (+2%, +10%) or less
than the set power-up zero
range (-2%, -10%).
Relieve load on scale or load
scale as appropriate
Powerup Motion
This message appears im
mediately after power-up if
the scale finds no stable
weight value within the set
power-up zero range
(±2%, ±10%).
Stabilize scale
Transfer error
Computer off or not ready
Turn on computer or start re
ceive program
Transfer cable defective or
plug not attached
Check transfer cable and plug
In an emergency, disable
data transfer in entries