![HBM WTX120 Operating Manual Download Page 109](http://html1.mh-extra.com/html/hbm/wtx120/wtx120_operating-manual_2111754109.webp)
SupervisorMode
WTX120
A4500-1.1
HBM: public
107
10.2.28
Coarse flow monitor time interval (Cors.mon.(s))
The command is used to monitor breakage (sack breakage) during the coarse
flow phase. Enter the increase in weight you expect per time interval in a nor
mal filling process. At the end of the coarse flow lockout time, the increase is
then checked after each time interval. If the weight increase rate is not ex
ceeded, the fact is interpreted as a breakage of the container being filled, and
dosing is aborted. Coarse flow fill flow monitoring is deactivated when the
coarse flow cut-off point is reached.
In the event of a breakage:
S
the coarse flow and fine flow are cut off;
S
in the dosing status (SDO), bit 6 (Alarm) is set to 1;
S
when the Fill flow On alarm is set, an alarm is triggered;
S
the dosing control goes to the stop condition.
10.2.29
Coarse flow lockout time (Lockout crs(s))
For the specified time after turning on the coarse flow, the comparison of the
actual weight against reaching of the coarse flow cut-off point is disabled. The
time does not delay the filling process.
In the case of chunky fill material, especially, it might happen that the first
items that drop into the container after the coarse flow starts generate load
spikes which immediately cause the coarse flow cut-off point to be exceeded.
You can prevent that with this setting. Experience shows that the lockout time
should be about 10 % of the coarse flow dosing time. If you are using the
coarse flow cut-off point monitor, the lockout time must be sufficient for mate
rial to enter the container.
Summary of Contents for WTX120
Page 1: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 3: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 184: ...Service password 182 A4500 1 1 HBM public WTX120 ...
Page 185: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 366: ...Service Passwort 182 A4500 1 1 HBM public WTX120 ...
Page 367: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 549: ...Mot de passe de service WTX120 A4500 1 1 HBM public 183 ...