SupervisorMode
92
A4500-1.1
HBM: public
WTX120
Menu
Key
Function/Secondary selection
Emptying
Time
Time-controlled emptying.
Only the
Time
parameter determines
the duration of the emptying process.
With the emptying time parameter (pa
rameter P1 > 0) you activate emptying.
Weight
Weight-controlled emptying
The Empty weight parameter specifies
the emptying limit. The emptying time
is additionally applied as the maximum
duration.
With the emptying time parameter (pa
rameter P1 > 0) you activate emptying.
Information
The emptying time starts immediately after checkweighing. Emptying is re
garded as complete when the emptying time is exceeded, regardless of
whether the scale is empty or not. During the emptying time a control output
can optionally be activated. When emptying is complete, the end of the filling
process is indicated by the Finished signal.
Information
Emptying starts immediately after checkweighing. Emptying is regarded as
complete when the gross weight is below the empty weight or when the empty
ing time is exceeded, regardless of whether the scale is empty or not. When
emptying is complete, the end of the filling process is indicated by the Finished
signal.
Summary of Contents for WTX120
Page 1: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 3: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 184: ...Service password 182 A4500 1 1 HBM public WTX120 ...
Page 185: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 366: ...Service Passwort 182 A4500 1 1 HBM public WTX120 ...
Page 367: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 549: ...Mot de passe de service WTX120 A4500 1 1 HBM public 183 ...