SupervisorMode
108
A4500-1.1
HBM: public
WTX120
Coarse flow
Lockout time
Weight
Time
Fig. 11.11 Coarse flow lockout time
10.2.30
Fine flow monitor time interval (Fine mon.(s))
The command is used to monitor breakage (sack breakage) during the fine
flow phase. Enter the increase in weight you expect per time interval in a nor
mal filling process. At the end of the fine flow lockout time, the increase is then
checked after each time interval. If the weight increase rate is not exceeded,
the fact is interpreted as a breakage of the container being filled, and dosing is
aborted. Fine flow fill flow monitoring is deactivated when the fine flow cut-off
point is reached.
If you enter the target weight the monitor is automatically deactivated.
Information
Select an increase in weight greater than the fluctuations caused by the mate
rial escaping during the filling process.
In the event of a breakage:
Summary of Contents for WTX120
Page 1: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 3: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 184: ...Service password 182 A4500 1 1 HBM public WTX120 ...
Page 185: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 366: ...Service Passwort 182 A4500 1 1 HBM public WTX120 ...
Page 367: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Page 549: ...Mot de passe de service WTX120 A4500 1 1 HBM public 183 ...