11 - Fault finding
11.8
33
Illegal
action
Steering not active - Over
speeding!
When speed is too high for steering (SafeTrack ESP).
SafeTrack is disabled.
Steering is enabled upon keypress SafeTrack auto.
Speed too high for steering - slow down!
43
34
Waiting
Start pump 2
Valves are positioned as in AutoWash table.
After press on softkey computer continues to next
step.
See also screen layouts.
Used by Autowash/AutoFill
Double pump must be started to flush hoses.
Stop and start Double pump with hydraulic lever, as
Warning prompts you to.
44
35
Waiting
Stop pump 2
Valves are positioned as in AutoWash table.
After press on softkey computer continues to next
step. See also screen layouts.
Used by Autowash/AutoFill
Double pump must be stopped to avoid chemical
in boom.
Stop and start Double pump with hydraulic lever, as
Warning prompts you to.
45
36
Waiting
Pause
Upon press of softkey or low or high PTO pump
RPM or Flexcap RPM
See also screen layouts
Used by Autowash/AutoFill
AutoWash is paused by keypress.
46
37
Warning
PrimeFlow Comm fault
Communication to PrimeFlow SMCU’s are failing.
Fault is probably due to broken cable or bad
connectors for power or data.
47
38
Warning
Output failing to sect 1
Detected by H-bridge on I2C bus
Output failing to sect 1
48
39
Warning
Output failing to sect 2
Detected by H-bridge on I2C bus
Output failing to sect 2
49
40
Warning
Output failing to sect 3
Detected by H-bridge on I2C bus
Output failing to sect 3
50
41
Warning
Output failing to sect 4
Detected by H-bridge on I2C bus
Output failing to sect 4
51
42
Warning
Output failing to sect 5
Detected by H-bridge on I2C bus
Output failing to sect 5
52
43
Warning
Output failing to sect 6
Detected by H-bridge on I2C bus
Output failing to sect 6
53
44
Warning
Output failing to sect 7
Detected by H-bridge on I2C bus
Output failing to sect 7
54
45
Warning
Output failing to sect 8
Detected by H-bridge on I2C bus
Output failing to sect 8
55
46
Warning
Output failing to sect 9
Detected by H-bridge on I2C bus
Output failing to sect 9
56
47
Warning
Output failing to sect 10
Detected by H-bridge on I2C bus
Output failing to sect 10
57
48
Warning
Output failing to sect 11
Detected by H-bridge on I2C bus
Output failing to sect 11
58
49
Warning
Output failing to sect 12
Detected by H-bridge on I2C bus
Output failing to sect 12
59
50
Warning
Output failing to sect 13
Detected by H-bridge on I2C bus
Output failing to sect 13
60
51
Warning
Output failing to bypass
61
52
Warning
Electronic fuse 1 is on
Voltage drop over electrothermal fuse
62
53
Warning
Electronic fuse 2 is on
Voltage drop over electrothermal fuse
63
54
Warning
Electronic fuse 3 is on
Voltage drop over electrothermal fuse
64
55
Warning
Electronic fuse 4 is on
Voltage drop over electrothermal fuse
65
56
Warning
RinseTank not full
When main tank has been filled and rinse tank is empty. Remember to re-fill rinse tank.
66
57
Warning
Main tank nearly empty
Main tank empty (tank gauge value set in menu 2.5.2).
Main tank is nearly empty. Consider distance
left before leaving field.
67
58
Warning
Sections OFF
If main ON/OFF is switched ON and one or more
sections are OFF.
Note that one or more sections are switched OFF.
68
59
Warning
Spray pressure too high
Spray pressure too high (limit set in menu 2.5.3.1). Decrease speed or change to nozzles with larger
capacity.
69
60
Warning
Spray pressure too low
Spray pressure too low (limit set in menu 2.5.3.2).
Change to nozzles of less capacity or increase
speed if safe.
70
ID
Type
Text at display detail
Criteria for fault
Operations disabled
Full screen Help text
Pr
Summary of Contents for ISOBUS VT
Page 2: ......
Page 4: ......
Page 8: ...Table of contents TOC 4 ...
Page 10: ...1 Welcome 1 2 ...
Page 12: ...2 Safety notes 2 2 ...
Page 48: ...5 Menu 1 Daily settings 5 2 ...
Page 52: ...6 Menu 2 Setup 6 4 ...
Page 74: ...8 Menu 4 Toolbox 8 4 ...
Page 78: ...10 Maintenance 10 2 ...
Page 103: ......