3 - Description
3.17
2. 1. 3.
03
time
Actual time
2. 1. 3.
04
Work rate
Rate shown in hectare per hour or acre per hour
2. 1. 3.
05
Actual volume rate
Actual rate in liter per hectare or gallon per acre
2. 1. 3.
06
Tank contents
Main tank contents
2. 1. 3.
07
Speed
Driving speed
2. 1. 3.
08
Volume sprayed
Readouts for Volume sprayed in currently active register
2. 1. 3.
09
Area sprayed
Readouts for Area sprayed in currently active register
2. 1. 3.
10
Active boom size
Active boom size including end nozzle
2. 1. 3.
11
Pressure
Displays spray pressure if sensor is fitted
2. 1. 3.
12
Fan speed
Displays Twin fan speed if sensor is fitted
2. 1. 3.
13
Wind Speed
Displays wind speed if sensor is fitted
2. 1. 3.
14
Pendulum lock status
Displays reading of pendulum lock sensor if fitted
2. 1. 3.
15
Pendulum unlock status
Displays reading of pendulum unlock sensor if fitted
2. 1. 3.
16
Dynamic center position
Displays Dynamic center position sensor if fitted
2. 1. 3.
17
Spray pump rev
Displays revolutions if sensor is fitted
2. 1. 3.
18
Extra sensor 1F
Readout from extra sensor 1 frequency
2. 1. 3.
19
Extra sensor 2F
Readout from extra sensor 2 frequency
2. 1. 3.
20
Extra sensor 3A
Readout from extra sensor 3 analog
2. 1. 3.
21
Extra sensor 4A
Readout from extra sensor 4 analog
2. 1. 3.
22
Voltmeter
Displays system voltage. Useful when fault finding
2. 1. 3.
23
Agitation
Agitation valve opening
2. 1. 3.
24
RinseTank content
RinseTank calculated content
2. 1. 3.
25
Slant angle
Headland assist angle sensor
2. 1. 3.
26
Boom height
Headland assist height sensor
2. 1. 3.
27
Reserved
R R
2. 1. 3.
28
Reserved
R R
2. 1. 3.
29
Reserved
R R
2. 1. 3.
30
Reserved
R R
2. 1. 3.
31
Reserved
R R
2. 1. 3.
32
Reserved
R R
2. 1. 3.
33
Nozzle size flow at 3 bar (45 psi)
Calculated nozzle flow at 3 bar (45 psi)
2. 1. 3.
34
2. 1. 3.
35
2. 1. 3.
36
2. 1. 3.
37
PF bus +
Voltage on PrimeFlow d
2. 1. 3.
38
PF bus -
Voltage on PrimeFlow databus -
2. 1. 4
Show lower right
2. 1. 4.
01
Programmed volume rate
Shows Programmed volume rate
2. 1. 4.
02
Boom flow
Boom flow rate per minute sprayed out through the boom
2. 1. 4.
03
time
Actual time
2. 1. 4.
04
Work rate
Rate shown in hectare per hour or acre per hour
2. 1. 4.
05
Actual volume rate
Actual rate in liter per hectare or gallon per acre
2. 1. 4.
06
Tank contents
Main tank contents
2. 1. 4.
07
Speed
Driving speed
2. 1. 4.
08
Volume sprayed
Readouts for Volume sprayed in currently active register
2. 1. 4.
09
Area sprayed
Readouts for Area sprayed in currently active register
2. 1. 4.
10
Active boom size
Active boom size including end nozzle
2. 1. 4.
11
Pressure
Displays spray pressure if sensor is fitted
2. 1. 4.
12
Fan speed
Displays Twin fan speed if sensor is fitted
2. 1. 4.
13
Wind Speed
Displays wind speed if sensor is fitted
2. 1. 4.
14
Pendulum lock status
Displays reading of pendulum lock sensor if fitted
2. 1. 4.
15
Pendulum unlock status
Displays reading of pendulum unlock sensor if fitted
2. 1. 4.
16
Dynamic center position
Displays Dynamic center position sensor if fitted
2. 1. 4.
17
Spray pump rev
Displays revolutions if sensor is fitted
2. 1. 4.
18
Extra sensor 1F
Readout from extra sensor 1 frequency
2. 1. 4.
19
Extra sensor 2F
Readout from extra sensor 2 frequency
2. 1. 4.
20
Extra sensor 3A
Readout from extra sensor 3 analog
Summary of Contents for ISOBUS VT
Page 2: ......
Page 4: ......
Page 8: ...Table of contents TOC 4 ...
Page 10: ...1 Welcome 1 2 ...
Page 12: ...2 Safety notes 2 2 ...
Page 48: ...5 Menu 1 Daily settings 5 2 ...
Page 52: ...6 Menu 2 Setup 6 4 ...
Page 74: ...8 Menu 4 Toolbox 8 4 ...
Page 78: ...10 Maintenance 10 2 ...
Page 103: ......