11 - Fault finding
11.7
17
Alarm
Reserved
Reserved, replaced by ID154-159
Error detection not active, profet error detection
not used.
On fault following occurs:
AutoWash disabled
AutoFill disabled
Used by Autowash/AutoFill
SuctionValve fault. Motor disconnected. Motor
short circuited or blocked. Sensor failing.
24
18
Alarm
TankGauge fault
When TankGauge is enabled and frequency is
below 50Hz.
AutoWash is disabled.
AutoFill is disabled.
Used by Autowash/AutoFill
TankGauge fault.
TankGauge frequency is detected below 50Hz.
25
19
Warning
Software error Terminal
Close hydraulic valves
Turn off PTO to stop spray. Turn off power to stop
hydraulics.
26
20
Warning
Software error JobCom
Close hydraulic valves
Turn off PTO to stop spray. Turn off power to stop
hydraulics.
27
21
Warning
Software error Grip
Close hydraulic valves
Turn off PTO to stop spray. Turn off power to stop
hydraulics.
28
22
Warning
Software error SetBox
Close hydraulic valves
Turn off PTO to stop spray. Turn off power to stop
hydraulics.
29
23
Warning
Software error FluidBox
Turn off PTO to stop spray. Turn off power to stop
hydraulics.
30
24
Warning
CAN bus failing to JobCom
Close hydraulic valves
Turn off PTO to stop spray. Turn off power to stop
hydraulics.
31
25
Warning
CAN bus failing to SetBox
Close hydraulic valves
Turn off PTO to stop spray. Turn off power to stop
hydraulics.
32
26
Warning
CAN bus failing to Grip
Close hydraulic valves
Turn off PTO to stop spray. Turn off power to stop
hydraulics.
33
27
Warning
CAN bus failing to FluidBox
Turn off PTO to stop spray.
Turn off power to stop hydraulics.
34
28
Illegal
action
Track Boom fold. Align sprayer
User starts to fold the boom, and the sprayer
trapeze is not locked.
BoomFoldInner is disabled.
Track Boom fold Align sprayer.
The alarm is present while the sprayer is not locked,
and a “fold inner” button is pressed. No folding
takes place.
38
29
Illegal
action
Track unfold Boom
Alarm for attempt to switch to “Manual” or “Auto”
mode in a situation where boom is not detected
unfolded.
When the boom is detected unfolded the trapeze
lock is unlocked and the message disappears.
Auto and manual is disabled.
Track unfold Boom.
Alarm for attempt to switch to “Manual” or “Auto”
mode in a situation where boom is not detected
unfolded.
Unfold the boom.
In half steer mode: Risk of bending folded side.
Contact service.
39
30
Illegal
action
Main on/off is on
When pressing softkey for BoomFlush, FastFlush,
MultiRinse while Main on off is on.
Keypress does not start process.
Used by Autowash/AutoFill
Main on off is on.
Turn Main ON OFF to off before starting AutoWash.
40
31
Illegal
action
MainTank not empty
When pressing softkey for BoomFlush, FastFlush,
MultiRinse while MainTank is not empty.
Keypress does not start process.
Used by Autowash/AutoFill
MainTank not empty. AutoWash cannot be started. 41
32
Illegal
action
No rinse water
When pressing softkey for either BoomFlush,
FastFlush, MultiRinse while RinseTank is calculated
too empty for that program.
Keypress does not start process.
Used by Autowash/AutoFill
Not enough rinse water for selected program.
AutoWash cannot be started.
42
ID
Type
Text at display detail
Criteria for fault
Operations disabled
Full screen Help text
Pr
Summary of Contents for ISOBUS VT
Page 2: ......
Page 4: ......
Page 8: ...Table of contents TOC 4 ...
Page 10: ...1 Welcome 1 2 ...
Page 12: ...2 Safety notes 2 2 ...
Page 48: ...5 Menu 1 Daily settings 5 2 ...
Page 52: ...6 Menu 2 Setup 6 4 ...
Page 74: ...8 Menu 4 Toolbox 8 4 ...
Page 78: ...10 Maintenance 10 2 ...
Page 103: ......