11 - Fault finding
11.13
135 Illegal
action
Keep folding 2
nd
outer wing.
When TERRA FORCE boom hydraulics set-up has
been selected in menu E8.6.3.7+8.
Wrong folding sequence.
Finish the folding of 2
nd
outer wing.
136
136 Warning
Lift the boom.
When TERRA FORCE boom hydraulics set-up has
been selected in menu E8.6.3.7+8.
The boom lift position is too low to ensure proper
function of the transport lock.
The boom lift position is too low to ensure proper
function of the transport lock.
137
137 Warning
Boom not in transport.
See state machine table “TERRA FORCE transport
lock and suspension relief”.
Place the boom correctly in transport position
before driving.
Check transport lock function.
Check boom height sensor.
138
138 Reminder
Mismatch Box and setup.
When setup in E8.5.8 Grip, SetBox, armrest does not
match jumper positions in SetBox PCB for armrest
and Outside switches.
Reminder is not sent when boxes are not
connected or software has no jumper positions PG
Setup in E8.5.8 Grip, SetBox, armrest does not
match jumper positions in SetBox PCB for armrest
and Outside switches.
139
139 Alarm
Dynamic center sensor.
When dynamic center function is enabled in menu
E.8.6.7
139
140 Alarm
Pendulum unlock sensor.
When TERRA FORCE boom hydraulics set-up has
been selected in menu E8.6.3.7
The alarm is generated:
•
if the sensor signal on AI5 is less than 0,5V.
•
Illegal transition. See table “TerraForce
Pendulum lock” in terminal specification ver
53
No or wrong signal from sensor. Shorted or
disconnected.
Check Pendulum unlock sensor adjustment and/or
connection.
9
141 Warning
Reg. Valve sensor fault.
140
142 Warning
Boom flow sensor fault.
141
143 Warning
Boom press sensor fault.
142
144 Warning
Pump sensor fault.
Used by Autowash/AutoFill
143
145 Warning
Reg. Valve motor fault.
144
146 Warning
Agitation sensor fault
Not used
11 Alarm Agitation valve fault is used instead
145
147 Warning
Agitation motor fault
Not used
11 Alarm Agitation valve fault is used instead
146
148 Warning
Centrifugal valve calib failed
When Regulation SW cannot detect and calculate X
axis crossing or slope of hydraulic valve
characteristic
Used by Regulation
149 Warning
Stack overflow
148
150 Warning
PF motor blocked #xxx
PrimeFlow. When command 09h is “Status
advanced” is read, each motor can be detected
blocked, shorted or disconnected.
The “#xxx” indicates the actual nozzle number.
A PrimeFlow motor is detected blocked.
Inspect motor and nozzle condition. Clean or
replace valve if necessary.
149
151 Warning
PF motor short #xxx
PrimeFlow. When command 09h is “Status
advanced” is read, each motor can be detected
blocked, shorted or disconnected.
The “#xxx” indicates the actual nozzle number.
A PrimeFlow motor is detected shorted.
Inspect motor and connector condition.
150
152 Warning
PF motor disconnect #xxx
PrimeFlow. When command 09h is “Status
advanced” is read, each motor can be detected
blocked, shorted or disconnected.
The “#xxx” indicates the actual nozzle number.
A PrimeFlow motor is detected disconnected.
Inspect motor, SMCU and connector condition.
151
ID
Type
Text at display detail
Criteria for fault
Operations disabled
Full screen Help text
Pr
Summary of Contents for ISOBUS VT
Page 2: ......
Page 4: ......
Page 8: ...Table of contents TOC 4 ...
Page 10: ...1 Welcome 1 2 ...
Page 12: ...2 Safety notes 2 2 ...
Page 48: ...5 Menu 1 Daily settings 5 2 ...
Page 52: ...6 Menu 2 Setup 6 4 ...
Page 74: ...8 Menu 4 Toolbox 8 4 ...
Page 78: ...10 Maintenance 10 2 ...
Page 103: ......