11 - Fault finding
11.5
Fault codes
Under these menus you can check if the communication is ok. This is used both by technicians and skilled operators.
To troubleshoot in field and see if CAN communication works, each computer unit has a LED, which indicates condition and
status of this computer.
•
It will give out light when the units are turned on.
•
If there is an error, a signal will show in a morse code if the CAN connection is damaged to that specific unit.
In the following is a full table of Alarms, Warnings etc. that will or can be shown on Terminal display.
÷
NOTE! These are useful for service staff:
ID is the fault identifier and is the number shown in the display.
Pr is alert priority.
ID
Type
Text at display detail
Criteria for fault
Operations disabled
Full screen Help text
Pr
01
Alarm
Sensor 12V supply failure
While the short circuit is present.
SafeTrack shifted to manual.
Auto is disabled.
Sensor 12V supply failure
1
02
Alarm
Sensor 5V supply failure
While the short circuit is present.
SafeTrack shifted to manual.
Auto is disabled.
Sensor 5V supply failure
2
03
Alarm
Track Lock sensor failure
Sensor signal is less than 0.5V.
All SafeTrack keys are disabled.
Manual tracking, “Align” and “Boom fold inner in” is
only possible from menu 4.7.
Track Lock sensor failure.
All SafeTrack keys are disabled.
Manual tracking, “Align” and “Boom fold inner in” is
only possible from menu 4.7.
3
04
Alarm
Trapeze lock locked illegally
Lock is detected locked unintentionally.
All SafeTrack keys are disabled.
Manual tracking, “Align” and “Boom fold inner in” is
only possible from menu 4.7.
Lock is detected released unintentionally.
Missing hydraulic pressure on lock cylinder. Mis
adjusted lock sensor.
Manual tracking, “Align” and “Boom fold inner in” is
only possible from menu 4.7.
4
05
Alarm
Trapeze lock not locking
Attempt to lock, but no “lock” signal on sensor
input.
All SafeTrack keys are disabled.
Manual tracking, “Align” and “Boom fold inner in” is
only possible from menu 4.7.
Attempt to lock, but no “lock” signal on sensor
input.
Lock sensor mis adjusted. Mechanical defect
prevents lock to penetrate hole. Mis adjusted rear
angle sensor.
Manual tracking, “Align” and “Boom fold inner in” is
only possible from menu 4.7.
12
06
Alarm
Trapeze lock released illegally
Lock is detected released unintentionally.
All SafeTrack keys are disabled.
Manual tracking, “Align” and “Boom fold inner in” is
only possible from menu 4.7.
Lock is detected released unintentionally.
Poor lock sensor adjustment. Lock cylinder fallen
off.
Manual tracking, “Align” and “Boom fold inner in” is
only possible from menu 4.7.
13
07
Alarm
Trapeze lock not released
When pressing auto to release lock but no “release”
signal from lock sensor.
Auto and manual are disabled.
Trapeze lock not released.
Attempt to release lock, but no “release” signal from
lock sensor.
No hydraulic pressure. Mis adjusted lock sensor.
Mechanical defect.
14
08
Alarm
Track Boom sensor failure
The boom sensor signal is less than 0.5V.
The boom sensor changes state, without “Boom
fold inner” button is active.
Auto and Manual is disabled.
Only “Align” function is possible.
Track Boom sensor failure.
Automatic and manual tracking is aborted.
Only “Align” function is possible.
15
Summary of Contents for ISOBUS VT
Page 2: ......
Page 4: ......
Page 8: ...Table of contents TOC 4 ...
Page 10: ...1 Welcome 1 2 ...
Page 12: ...2 Safety notes 2 2 ...
Page 48: ...5 Menu 1 Daily settings 5 2 ...
Page 52: ...6 Menu 2 Setup 6 4 ...
Page 74: ...8 Menu 4 Toolbox 8 4 ...
Page 78: ...10 Maintenance 10 2 ...
Page 103: ......