3 - Description
3.23
4. 5.
4. 1. 9
Speed to terminal
4. 5. 4.
2
Freq. 2 input Extra
Test of frequency 2 sensors: Extra Regulation, agitation valve
4. 5.
4. 2. 1
Regulation valve
4. 5.
4. 2. 2
Agitation valve
4. 5.
4. 2. 3
Boom folded Left
4. 5.
4. 2. 4
Boom folded Right
4. 5. 4.
3
Switch on/off inputs
Test Switch inputs function 0 equals connected, 1 equals open
4. 5.
4. 3. 1
Pendulum lock
4. 5.
4. 3. 2
Ladder up
4. 5.
4. 3. 3
HY interface error
4. 5.
4. 3. 4
SmartValve switch
4. 5.
4. 3. 5
Main tank float
4. 5.
4. 3. 6
Rinse tank float
4. 5.
4. 3. 7
12V relay DAH box
4. 5.
4. 3. 8
Foot Switch terminal
(HC6500 only)
4. 5. 4.
4
Analog 1 inputs Boom
Test Analog 1 sensors on boom: Slant, Height, Tilt, Foam, TWIN
4. 5.
4. 4. 1
Slant
4. 5.
4. 4. 2
Boom height
4. 5.
4. 4. 3
PF bus +
4. 5.
4. 4. 4
PF bus -
4. 5.
4. 4. 5
Foam blob distance
4. 5.
4. 4. 6
TWIN angle
4. 5.
4. 4. 7
TWIN fan r/min
4. 5.
4. 4. 8
Agitation angle
4. 5.
4. 4. 9
Reg. valve angle
4. 5. 4.
5
Analog 2 inputs Extra
Test Analog 2 sensors: Electric smart valves, extra
4. 5.
4. 5. 1
Distance center
4. 5.
4. 5. 2
PrimeFlow volt left
4. 5.
4. 5. 3
PrimeFlow volt right
4. 5.
4. 5. 4
Dynamic center pos.
4. 5.
4. 5. 5
Lock sensor
4. 5.
4. 5. 6
Pendulum lock
4. 5.
4. 5. 7
Suction SV potmeter
4. 5.
4. 5. 8
Press. SV potmeter
4. 5.
4. 5. 9
Fill valve potmeter
4. 5. 4.
6
Track sensor test
Actual sensor signals Under 0.5 volt means not connected
4. 5.
4. 6. 1
Front sensor
4. 5.
4. 6. 2
Front sensor
4. 5.
4. 6. 3
Rear sensor
4. 5.
4. 6. 4
Rear sensor
4. 5.
4. 6. 5
Boom sensor 1
4. 5.
4. 6. 6
Boom sensor 1
4. 5.
4. 6. 7
Boom sensor 2
4. 5.
4. 6. 8
Lock sensor
4. 5.
4. 6. 9
Lock sensor
4. 5. 4.
7
SafeTrack sensitivity view
Higher offset higher current to open Higher gain mean more oil at current
4. 5.
4. 7. 1
Left offset value
4. 5.
4. 7. 2
Right offset value
4. 5.
4. 7. 3
Left gain factor
4. 5.
4. 7. 4
Right gain factor
4. 5. 4.
8
Twin boom fold sensors
Status=1 is 5 volt or not connected Under 0.5 volt is not connected
4. 5.
4. 8. 1
L outer boom transp.
4. 5.
4. 8. 2
L outer boom spray
4. 5.
4. 8. 3
R outer boom transp.
4. 5.
4. 8. 4
R outer boom spray
4. 5. 4.
9
Speed, Pumps RPM mounting
Duty cycle indicate distance 70% = too close 20%= too far away
4. 5.
4. 9. 1
Speed
Summary of Contents for ISOBUS VT
Page 2: ......
Page 4: ......
Page 8: ...Table of contents TOC 4 ...
Page 10: ...1 Welcome 1 2 ...
Page 12: ...2 Safety notes 2 2 ...
Page 48: ...5 Menu 1 Daily settings 5 2 ...
Page 52: ...6 Menu 2 Setup 6 4 ...
Page 74: ...8 Menu 4 Toolbox 8 4 ...
Page 78: ...10 Maintenance 10 2 ...
Page 103: ......