4 - System setup
4.7
TWIN Preset
Air volume and air angle can be set in 2 different positions:
•
Headwind
•
Tail wind
Store manual preset
1.
Set air volume and air angle for headwind.
2.
Press a long key press at button for position 1 on the grip to store the present setting.
3.
Do the same setting for position 2 tailwind.
Store auto preset
TWIN preset can be setup so it will shift automatically from position 1 to position 2 when the main ON/OFF is activated
(menu 2.2.5 to 2.2.5.2).
Spraying with DynamicFluid4 pressure regulation
Start up procedure and steps done by the spray driver when beginning a spray job at the headland in the field is described
below:
•
The controller always starts up in automatic mode.
•
If, by some reason, the
or
has been pressed, the controller enters manual mode. Then press
before
beginning any spraying.
•
Do not adjust the pressure before and while spraying, as the controller does this automatically.
Regulation valve LED’s
The regulation valve is equipped with 4 LED’s as indication of valve status:
LED color
Valve status
2 x Red
Out of working range.
The valve disc is out of its normal working range. This does not happen when the regulation valve works correctly. The software will prevent the
valve from going out of range, also when manually operated.
Yellow
Valve closed.
The valve disc is closed or starts to open, and is within the normal working range.
Green
Open and in work range.
The valve disc is open and in its normal working range. This is normal state when spraying.
Summary of Contents for ISOBUS VT
Page 2: ......
Page 4: ......
Page 8: ...Table of contents TOC 4 ...
Page 10: ...1 Welcome 1 2 ...
Page 12: ...2 Safety notes 2 2 ...
Page 48: ...5 Menu 1 Daily settings 5 2 ...
Page 52: ...6 Menu 2 Setup 6 4 ...
Page 74: ...8 Menu 4 Toolbox 8 4 ...
Page 78: ...10 Maintenance 10 2 ...
Page 103: ......