Digital channel
:can change trigger threshold of the digital channel by setting the threshold
voltage.
Trigger setting1:
Data source:CH3;Baud rate:1000000;When:start bit;Free level:low.Adjust the trigger level,
and the trigger result is shown as follows:
Trigger setting 2:
Data source: CH3;Baud rate:1000000;When:data frames and data;Identifier:12efabcd;
Data1:0xa8;Data2:0xa9;Data3:0xaa;Data4:0xab;Free level: low;Mode:normal.Adjust the
trigger level, and the trigger result is shown as follows:
CAN decoding interpretation:
1. Decoded data is displayed in hexadecimal;
2. The display color of "frame ID" and "check bit" is purple, and the display color of "data"
is orange;
3. When "?"or"please adjust the time base"appears ,the time base needs to be adjusted to
get the decoded result.