DPO6000
,
MPO6000 Series Digital Phosphor Oscilloscope Instruction V1.1
- 105 -
DC offset accuracy
±0.1 div±2 mV±1% offset value
Theisolationofchannels
DC maximum bandwidth:>40 dB
Note
: Bandwidth reduced to 6MHz when using a 1X probe.
Vertical
(digital
channels)(used
for
MPO6000DMPO/6000EDU
and
DPO6000B/DPO6000C after buying digital probes LP104)
Threshold value
4 channels in 1 group adjustable threshold value
Threshold option
TTL(1.4 V)
5.0 V CMOS(+2.5 V)
3.3 V CMOS(+1.65 V)
2.5 V CMOS(+1.25 V)
1.8 V CMOS(+0.9 V)
ECL(-1.3 V)
PECL(+3.7 V)
LVDS(+1.2 V)
0V
User-defined
Threshold range
±7.0V,10mV step by step
Threshold accuracy
±(100mV+3% threshold setting)
Dynamic range
±5.0V+ threshold
Minimum
voltage
swing
500 mVpp
Vertical resolution
1 bit
Trigger
Triggerlevelrange
±5 divisions from the center of the screen
Trigger mode
auto
、
general
、
single
Level
CH1~CH4
±4 divisions from the center of the screen.
Holdoff range
8ns~10s
Trigger level
accuracy
CH1~CH4
0.2 div×volts/div within ±4 divisions from the
center of the screen
Edge trigger
Slope
Rising edge,falling edge,rising or falling edge
Signal source
CH1~CH4,
D1.0~D1.3,
D2.0~D2.3,